Garland XPE12 Service Manual page 78

Electric/gas dual side xpress plus grill
Table of Contents

Advertisement

Component Check Procedures
12. When replacing the
actuator ensure that
no wires are trapped
between it the
bottom frame. Do
install the actuator
clams bracket yet.
13. Make sure that the
actuator is aligned
with the shaft before
securing together
with the clevis pin.
Secure clevis pin with
the clip at the end of
the pin.
14. Secure actuator and
reattach the actuator
clamp brackets.
15. Reattach the limit switch bracket to the unit.
Tighten the bolt/lock nut gently, over tightening
may cause damage. Make sure all connector on
the switches still in secure in place. Keep harness
away from sharp edges, and moving objects.
Provide enough room for protection from
hazards place tie wraps for support.
78
16. Slide the anti-rotate
into the unit from
the top of the slot
and secure back
to the actuator
shaft. Tighten the
bolts gently, over
tightening may cause
damage.
17. Route the harness through and around open
areas. Provide extra protection from hazard and
also provide places for the tie wraps, clips and
other supports. Plug in the motor connector and
the encoder connector very gently, make sure
the connectors are secure in place.
18. Installation completed, turn power on and test
the unit.
Document: GAR_SM_4601777 (4/16)
Section 7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents