2. Safety
2.4
Warning notices
Be sure to observe this information. Failure to do so may result in personal injury or damage to property!
Ensure that the machine cabinet is not installed above or in the direct vicinity of water
vessels. There is a risk of electric shock if improperly installed.
Installation loca-
tion
Only connect the machine cabinet to a correctly installed 230 V socket or earth cable
which is fused with an upstream 16 A fuse.
Electrical equipment connected to the mains may be damaged during a storm. We
would recommend fitting surge protection in the building to protect against this.
Mains connection
The connection cable must be laid in a way it won't represent a tripping hazard.
The control unit must not be fitted or activated in environments with potential explo-
sive atmospheres or in places where there are flammable materials. Sparks in such
environments may cause an explosion or fire and this may result in physical injuries
Explosive atmos-
or even death.
pheres
The control unit may cause medical equipment to malfunction. This device should
therefore not be used in close proximity to medical equipment.
Interferences
The control unit must not be operated if the housing or cable insulation is damaged or
crushed.
Damage
Service work on the machine cabinet may only be undertaken by authorised special-
ists / electricians.
Service work
The power supply must be ensured at all times. Please ensure that the fuse on the
control cabinet is sufficient (16 A). Additional electrical fixtures on the same fuse may
disrupt operation.
Voltage supply
5 / 40