Safety Note

The design of this meter is accordance with IEC61010 clause (the
safety standard issued by International Electro technical Commission).
Prior to the operation of the instrument, please read the safety
considerations before use.
1. When DC voltage above 30V, AC voltage above 25V, current above
10mA, AC power line with inductive load or power line during electric
fluctuation is measured, please beware of electric shock.
2. Prior to measurement, check if the measurement function switch is at
the correct position. Check if the test lead is contacted reliably,
connected correctly, and grounded well, etc. in order to avoid electric
shock.
3. Only if the meter is used with the matched test lead, it can meet the
requirement of safety standard. When the line of the test lead is
damaged, it is necessary to replace another one of the same model or
the same electrical specification.
4. Don't use other unconfirmed or disapproved fuse to replace the fuse
inside the meter. Only the same model or same specification fuse can be
replaced. Before the replacement, the test leads must be removed from
the measuring point to ensure there is no longer any signal at the input
terminal.
5. Don't use other unconfirmed or disapproved battery to replace the
battery inside the meter. Only the same model or same electrical
specification battery can be replaced. Before replacement, the test lead
must be removed from the measuring point to ensure there is no longer
any signal at the input terminal.
6. When electrical measurement is made, never let your body get in touch
with ground directly, and don't touch uncovered metal terminal, output
port, lead clamp, etc. where earth potential may exist. Dry clothes, rubber
shoes, rubber cushion and other insulating material are usually used to
keep your body insulated against ground.
7. Don't store and use it in the high-temperature, high-humidity,
inflammable and strong magnetic field environment.