Bypass Mode; Mixed Mode; Cooler Mode - Mercedes-Benz OM 471 Introduction Into Service Manual

Introduction of engine om 471 and exhaust aftertreatment
Table of Contents

Advertisement

System components

Bypass mode

1
Oil/coolant module
2
Coolant thermostat
3
Coolant pump
KA
Coolant outlet (to engine)
KE1 Coolant inlet (from bypass line)
KE2 Coolant inlet (from cooler)
The coolant thermostat (2) is closed for a coolant inlet
temperature < 87∞C. The coolant only circulates in the engine.
The vehicle heating heat exchanger can, however, be flowed
through.

Mixed mode

1
Oil/coolant module
2
Coolant thermostat
3
Coolant pump
KA
Coolant outlet (to engine)
KE1 Coolant inlet (from bypass line)
KE2 Coolant inlet (from cooler)
For a coolant inlet temperature > 87∞C and < 95∞C the coolant
thermostat (2) opens partially and the coolant flows at the same
time through the engine radiator and the short circuit line to the
coolant thermostat (2).

Cooler mode

1
Oil/coolant module
2
Coolant thermostat
3
Coolant pump
KA
Coolant outlet (to engine)
KE1 Coolant inlet (from bypass line)
KE2 Coolant inlet (from cooler)
The coolant thermostat (2) is completely open for a coolant inlet
temperature > 95∞C. The coolant is fully fed to the engine
radiator.
196
– This printout will not be recorded by the update service. Status: 09 / 2011 –
W20.10>1073>81
W20.10>1074>81
W20.10>1075>81

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents