An Error Message Appears

This describes the error messages that may appear on the machine's display and how to take
action to remedy the problem. If the action described here does not correct the problem or if an
error message not described here appears, contact your authorized Roland DG Corp. dealer.
[CLOSE COVER (FRONT COVER/COVER L/COVER R)]
Close the front, left, or right cover. For safety, the carriage does not operate while a cover is open.
[OPTION-DRYER IS NOT CONNECTED]
When the optional dryer is not connected to the printer, [OPTION DRYER] is set to "ENABLE." Switch the sub
power and main power off, and then connect the optional dryer to the printer.
 P. 89, "Using an Optional Dryer"
[HEATING TIMEOUT CONTINUE?]
The media heating system did not reach the set temperature.
This occurs because the temperature of the location where the machine is installed is too low. We recommend
raising the temperature. To continue waiting for the temperature to rise, press
. To start printing
immediately, press
.
[CAN'T PRINT CROP CONTINUE?]
The size of the data including the crop marks is larger than the printing area of the loaded
media.
To continue performing output without correcting this, press
. At this time, the crop marks and
the portion extending beyond the printing area are not output. To stop output, stop sending data from the
computer, and then raise the loading lever. Make the printing area wider, for example by replacing the media
with a larger piece of media, and then send the data again.
The size of the data being output is too small.
Make the horizontal-direction (scan-direction) size of the data at least 65 mm (2.6 in.). To continue performing
output without correcting this, press
. At this time, the data is output without printing the crop marks.
To stop output, stop sending data from the computer, and then raise the loading lever. Increase the size of the
data, and then send the data again. There is no limitation on the size of the data in the media-feeding direction.
[TEMPERATURE IS TOO HIGH **°C]
The temperature of the location where the machine is installed has risen above the ambient
6
temperature at which the machine can operate.
Operation cannot be continued. Switch off the sub power. The displayed temperature is the current ambient
temperature of the installation location. Bring the installed location to a temperature at which operation is
possible (15 to 32°C [59 to 90°F]), allow the machine to come to room temperature, and then turn on the power.
[TEMPERATURE IS TOO LOW **°C]
The temperature of the location where the machine is installed has fallen below the ambient
temperature at which the machine can operate.
Operation cannot be continued. Switch off the sub power. The displayed temperature is the current ambient
temperature of the installation location. Bring the installed location to a temperature at which operation is
possible (15 to 32°C [59 to 90°F]), allow the machine to come to room temperature, and then turn on the power.