 Other problems
Problem
Suction power
becomes weak
or stops during
operation.
Suction power
becomes weak
or stops during
operation.
(Filter indicator
lamp is flashing).
The operation
sound increased.
The cleaner does
not operate, or
stops during
operation
Operating time is
short even after
charging
The exhaust or body gets
warm (during operation)
The body or charging
station gets warm
(while charging)
An abnormal odor is
coming from the exhaust
There is an
abnormal sound
coming from
around the dust
case
Things to check
Is the remaining battery level low?
[Battery indicator lamp is flashing (about two times per second)]
Is the exhaust abnormally hot?
When continuously operating on "High" in places of high temperature, such as under direct sunlight or in
cars exposed to the sun, the safeguard might operate and the suction power might become weak to prevent
the body motor and battery from overheating.
Is the dust case full of dust?
Is dust stuck in the filters?
Is dust clogging the body air duct?
Is dust clogging the power head or mini power head?
Did you vacuum fine sand or dust?
Is the remaining battery level low?
Is the cleaner set on the charging
station?
When the battery gets hot, the body might stop
automatically to prevent the battery from overheating.
Did you leave the body unattended
for a long period of time without
charging it?
Is the battery exhausted?
The motor is being cooled via air flow, which is normal.
It gets warm due to the flow of electrical current to the control circuit, which
is normal.
Is dust stuck in the filters?
Are the filters thoroughly dried after washing?
Are the clean filter and dust case securely attached?
Is dust clogging the body air duct?
Instructions
Set the body on the charging station
for charging.
Stop operation by pressing the control button. Wait for
the body to cool down, and then start operation again.
Empty the dust case.
Clean the filters (wash with water).
Remove the dust
using disposable
chopsticks, etc.
Body air duct
Remove the dust.
Empty the dust case and perform
maintenance (wash with water) on
the filters.
Set the body on the charging station
for charging.
Detach it from the charging station.
Wait for the body to cool down, and
then start operation again.
The battery capacity might be temporarily recovering
poorly. Repeat the procedure of using the cleaner until
the battery is exhausted and charging fully 2 or 3 times.
If the operating time is particularly short even after
charging correctly or maintaining the filters washing
with water, the battery is exhausted. Please consult
with the Hitachi authorized service agent.
Clean the filters (wash with water).
After washing, thoroughly air dry the filters.
Securely attach them.
Remove the dust
using disposable
chopsticks, etc.
Body air duct
Page
P.E-11
P.E-12
P.E-34
P.E-20 to E-22
P.E-23, P.E-24
P.E-27 to E-29
-
Disposable
chopsticks
P.E-30 to E-33
P.E-20 to E-24
P.E-27 to E-29
P.E-11
-
P.E-12
P.E-11
P.E-20 to E-24
P.E-27 to E-29
-
-
P.E-27 to E-29
P.E-23 to E-25
-
Disposable
chopsticks
E-35