Select Submenu 5 "Change AIS Mode" with cursor button [Up] & [Down] by pressing No. 5
on the keyboard.
Toggle the AIS Mode between the configurations of "High Seas" and "Inland AIS". Main parts
of the technical performance of the NAUTICAST are in relation to this setting. In the "High
Seas" mode menus will have different appearance. Toggle the values you want to use and
press [Save] to store input data. Press [Back] to return to the Submenu without saving.
NOTE: Changes of the reporting rate setting should be done very carefully.
Possible reporting rate values are: "as given by the autonomous mode"; "once every 10
minutes"; "once every 6 minutes"; "once every 3 minutes"; "once every minute"; "once every
30 seconds"; "once every 15 seconds"; "once every 10 seconds"; "once every 5 seconds";
"next higher reporting rate"; "next lower reporting rate"; "once every 2 seconds"
Y1-03-0211 Rev D
o
o
N 1
21' E
0
14' |1>0.01|2>1.30|3>1.80nm
|----------------------------------
| 6. Service Configuration
-----| |
| +- 1. Change Service Password
View | +- 2. User Password Settings
| +- 3. Change MMSI / IMO
-----| +- 4. Change DAC / ESN
| +- 5. Change AIS Mode
Msg. | +- 6. Restore Factory Settings
|
-----|
|
Displ|
----------------------------------------
NUM| Select->|
o
o
N 1
21' E
0
14' |1> N/A|2>0.00|3>0.10nm
*************** AIS Mode ***************
AIS Mode: <Inland AIS> / <High Seas>
Rep.Rate: <as given by autonom. mode>
----------------------------------------
NUM|
Save
|
|
|<-Back
|