3:1062 + (n-1)
Kinetic Energy – Entry n
n = 1 to 120
3:1282 – 3:1500
Reserved
3:1501
Slave Access Failure Type
This register may be read to view details of
the last Slave Device Failure or Illegal Data
Address exception response.
3:1502
Slave Access Failure Bank
Contains the Modbus bank in which the last
Slave Device Failure or Illegal Data Address
exception response occurred. The bank
returned does not include any address
information.
3:1503
Slave Access Failure Register
Contains the register number at which the
last Slave Device Failure or Illegal Data
Address exception response occurred. The
address returned does not include any
bank information. For example, abcd is
returned for an error at address 0:abcd,
1:abcd, 3:abcd, or 4:abcd.
3:1504 – 3:1510
Reserved
3:1511
Number of Log Entries
Modbus Error Log
Firmware Error Log
24
Read
0 – 315.0 J (0 – 2788.2 lbs-in)
N/A
0 – 12
0 – 4
0 – 65535
N/A
0 - 10