Table 11 - Available Input Registers - ETC Sasquatch User Manual

Table of Contents

Advertisement

Register
1:0012
1:0013
1:0014
1:0015
1:0016
Input Registers

Table 11 - Available Input Registers

Register
3:0001 – 3:0002
Description
New Velocity Indicator
Kinetic Energy Alarm Status
Consecutive Hard Arrival Alarm Status
Dangerous Arrival Alarm Status
Cumulative Hard Arrival Alarm Status
Cumulative Kinetic Energy Alarm Status
Description
Controller Information
Serial Number
Read
0 – No new velocity measured
since last polled
1 – New velocity measured since
last polled (value resets to 0 once
it has been read)
0 - Consecutive Hard Arrival
Statistic under threshold
1 - Consecutive Hard Arrival
Statistic over threshold
0 - Dangerous Arrival Alarm
Statistic under threshold
1 - Dangerous Arrival Alarm
Statistic over threshold
0 - Cumulative Hard Arrival Alarm
Statistic under threshold
1 - Cumulative Hard Arrival Alarm
Statistic over threshold
0 - Cumulative Kinetic Energy
Alarm Statistic under threshold
1 - Cumulative Kinetic Energy
Alarm Statistic over threshold
Read
Double Word format: 0 - 99999
21

Advertisement

Table of Contents
loading