Time And Items Required - Brocade Communications Systems 6520 Reference Manual

96-port auto-sensing 2, 4, 8, or 16 gbps as well as 10 gbps fibre channel (fc) switch
Hide thumbs Also See for 6520:
Table of Contents

Advertisement

DRAFT: BROCADE CONFIDENTIAL
DANGER
Disconnect the power cords from all power sources to completely remove power from the
chassis.

Time and items required

Replacing a power supply in the Brocade 6520 should require less than two minutes to complete.
You need the following items to replace a power supply in a Brocade 6520:
A new power supply that has the same part number and airflow indicator as the power supply
being replaced - refer to
1
2
3
4
FIGURE 8
Brocade 6520 Hardware Reference Manual
53-1002705-01
At the command prompt, enter the psShow command to display power supply status as
shown below:
br6520:admin> psshow
Power Supply #1 is OK
V10529,
TQ2H0000030
,2X,TQ2H0000
Power Supply #2 is OK
V10541,
TQ2H0000189
,TQ2H0000
br6520:admin>
Figure 8
Power supply #2
Grounding screw
Handle
AC input status LED
Brocade 6520 power supply detail
Power supply removal and replacement
,60-0300031-01,X2,
,60-0300031-01,X3,
on page 27 for the location of the airflow labels
5
Locking tab
6
DC output status LED
7
Airflow label
8
Power cord receptacle
4
,SP640
,SP640-2P
,A
27