Technical Data - Graco 5:1 Fire-Ball 300 Instructions Manual

Table of Contents

Advertisement

Technical Data

Technical Data
.
®
5:1 Fire-Ball
300 Pumps
Maximum fluid working pressure
Fluid pressure ratio
Air pressure operating range*
Maximum air consumption
Pump cycles per gallon (liters)
Recommended speed for optimum pump life
Maximum recommended pump speed
Wetted Parts
Sound pressure level (measured at 1 meter
from unit)
Sound power level (tested in accordance with
ISO 9614-2)
Approximate weight
®
Loctite
is a registered trademark of the Loctite Corporation.
14
US
900 psi
40 to 180 psi
3
13 ft
/minute for first gpm
pumped at 100 psi up to 8 addi-
3
tional ft
/min for each additional
gpm with pump operated within
recommended range
30
70 cycles per minute
130 cycles per minute 5 gpm
Steel, aluminum, buna-N, urethane
17 lb
3
(m
Metric
6.2 MPa, 62 bar
5:1
0.28 to 1.2 MPa, 2.8 to 12 bar
3
0.096 m
/minute for first lpm
pumped at 0.7 MPa, 7 bar up to
0.058 additional m
additional lpm with pump oper-
ated within recommended range
7.9
130 cycles per minute 19 lpm
77.8 dB(A)
85.6 dB(A)
7.7 kg
/min)
3
/min for each
306518ZAE