Do you have a question about the PanelView Plus 400 and is the answer not in the manual?
Questions and answers
Prisciliano Evangelista Evangelista Pablo
May 15, 2025
como calibrar pantalla
2 comments:
Prisciliano Evangelista Evangelista Pablo
May 15, 2025
@Prisciliano Evangelista Evangelista Pablo
Mr. Anderson
May 22, 2025
To calibrate the screen on an Allen-Bradley PanelView Plus 400:
1. Enter configuration mode. 2. Select: Terminal Settings > Touch Screen > Calibration. 3. Follow the on-screen instructions to touch the screen four times. 4. If the touches are not accurate, the system will request more until calibration is successful.
This answer is automatically generated
Related Manuals for Allen-Bradley PanelView Plus 400
About This Publication This document provides instructions on how to install these devices in a panel: • PanelView Plus 400 keypad terminal or keypad and touch terminal • PanelView Plus 600 keypad, touch, or keypad and touch terminal • PanelView Plus Compact 400 keypad terminal or keypad and touch terminal •...
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://literature.rockwellautomation.com) describes some important differences between solid state equipment and hard-wired electromechanical devices.
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Environment and Enclosure This equipment is intended for use in a Pollution Degree 2 industrial environment, in ATTENTION overvoltage Category II applications (as defined in IEC 60664-1), at altitudes up to 2000 m (6561 ft) without derating.
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Hazardous Locations This equipment is suitable for these locations: • Class I, Division 2 Groups A, B, C, D • Class II, Division 2 Groups F, G • Class III •...
Page 5
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Environnements dangereux Cet équipement ne peut être utilisé que dans les environnements suivants : • Classe I, Division 2, Groupes A, B, C, D ; • Classe II, Division 2, Groupes F, G ; •...
Page 6
National Electrical Code, article 500. 400 and 600 Terminals Control Drawing Associated Nonincendive Field Wiring Apparatus Nonincendive Field PanelView Plus 400/600 Host Product Wiring Apparatus Nonincendive Field Wiring Peripheral Device...
Page 7
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Application Information Per the National Electrical Code the circuit parameters of nonincendive field wiring apparatus for use in hazardous locations shall be coordinated with the associated nonincendive field wiring apparatus such that their combination remains nonincendive. The 400 and 600 terminals and the USB peripheral device shall be treated in this manner.
2711P-TD001. You can find this publication in the Literature Library at http://literature.rockwellautomation.com. About the Product The base configured unit of the PanelView Plus 400 and 600 terminals includes these components: • Power supply, AC or DC • Display with keypad, touch screen, or keypad and touch screen •...
• USB, RS-232, and Ethernet Ports or • USB, RS-232, and Ethernet Ports with Interface for Communication Module. When using the DH-485 module, catalog number 2711P-RN3, with PanelView Plus 400 IMPORTANT and 600 terminals, the cable length must not exceed 30 m (98 ft) to comply with CE requirements.
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Install the Terminal Before installing the terminal in a panel, review these topics: • Mounting clearances • Panel cutout dimensions • Product dimensions Mounting Clearances Allow adequate clearance around the terminal, inside the enclosure, for adequate ventilation. Consider heat produced by other devices in the enclosure.
Page 11
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Follow these steps to mount the terminal in a panel. 1. Cut an opening in the panel using the panel cutout that shipped with the terminal. 2. If a communication module is ordered separately, attach the module to the base unit before panel installation.
Page 12
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals 7. When all levers are in place, slide each lever an additional notch or two until you hear a click. 8. Rotate each lever in the direction indicated until it is in the final latch position. Follow the latching sequence for the optimum terminal fit.
Page 13
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Product Dimensions The illustrations show approximate product dimensions for the PanelView Plus and PanelView Plus Compact 400 and 600 terminals. Measurements are in mm (in.). 400 Terminal Dimensions 400 Keypad or Keypad and Touch (6.0) (7.28)
Page 14
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals 600 Terminal Dimensions 600 Keypad or Keypad and Touch (6.58) (10.47) (2.68) (3.86) 71 (2.81) 154 (6.08) 600 Touch (6.0) (7.28) 68 (2.68) (3.86) 71 (2.81) 154 (6.08) Publication 2711P-IN002G-EN-P - November 2009...
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Remove and Install the Power Terminal Block The terminals ship with a power block installed. You can remove the power terminal block for ease of installation, wiring, and maintenance. Explosion Hazard WARNING Substitution of components may impair suitability for hazardous locations.
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals DC Power Connections PanelView Plus devices with an integrated, nonisolated, DC power supply have these power ratings: • 24V DC nom (18…30V DC) • 25 W max (1.0 A at 24V DC) The power supply is internally protected against reverse polarity of the DC+ and DC- connections.
Page 17
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Functional Earth Connection PanelView Plus devices with a DC power input have a functional earth terminal that you must connect to a low-impedance earth ground. The functional earth connection is on the power input terminal block.
Page 18
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Connect DC Power Explosion Hazard - Do not disconnect equipment unless power has been switched off and WARNING area is known to be nonhazardous. Disconnect all power before installing or replacing components. Failure to disconnect power may result in electrical shock and/or damage to the terminal.
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals AC Power Connections The 400 to 600 terminals with an integrated AC power supply have these power ratings: • 85…264V AC (47…63 Hz) • 60V A maximum The input power terminal block is removable and supports these wire sizes. Wire Specifications for AC Input Power Terminal Block Terminal Screw Wire Type...
Page 20
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Connect AC Power Explosion Hazard - Do not disconnect equipment unless power has been switched off and WARNING area is known to be nonhazardous. Disconnect all power before installing or replacing components. Failure to disconnect power may result in electrical shock and/or damage to the terminal.
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Troubleshooting If the terminal is not operating correctly, check the power, display settings, status indicators, and review the system startup and error messages. Check for Adequate Power A terminal that does not receive adequate power could cause unpredictable behavior. Verify the power requirements in the Specifications table.
Page 22
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals The table shows indicator states if the terminal powers on and stops during startup. Indicator States If the Terminal Stops During Startup Fault (Red) Comm (Green) Description Indicator Indicator Last firmware download failed. Reload firmware using Firmware Upgrade Wizard (FUW) utility.
Page 23
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Check the Display If the terminal display is dim or unreadable: • check the brightness setting. From terminal Configuration mode, choose Terminal Settings>Display Intensity. • check the contrast setting. From terminal Configuration mode, choose Terminal Settings>Display Contrast.
Page 24
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Startup Error Messages When an error occurs, the terminal displays an error number with a text message. The word ERROR! appears under the message in different languages. # Displayed Message ERROR! FEHLER! ERREUR! ERRORE! Error # Message...
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Battery Removal The 400 and 600 terminals contain a lithium battery that is permanently connected and should be removed only by trained professionals. This product contains a hermetically sealed lithium battery which may need to be replaced during the life of the product.
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Specifications PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Attribute Value Display 400 and 600 grayscale display Grayscale passive matrix, film compensated super-twist nematic (FSTN) LCD technology 400 and 600 color display Color active matrix, thin film transistor (TFT) LCD technology Display size, Approx., diagonal 400 grayscale display...
Page 27
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Dimensions (HxWxD), approx. 400 keypad, or keypad and touch 152 x 185 x 90 mm (6.0 x 7.28 x 3.54 in.) 600 keypad, or keypad and touch 167 x 266 x 98 mm (6.58 x 10.47 x 3.86 in.) 600 touch...
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Certifications Certification c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E10314. UL Listed Industrial Control Equipment for use in: • Class I, Div 2, Group A, B, C, D •...
Page 29
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Publication 2711P-IN002G-EN-P - November 2009...
Page 30
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Publication 2711P-IN002G-EN-P - November 2009...
Page 31
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals Publication 2711P-IN002G-EN-P - November 2009...
Need help?
Do you have a question about the PanelView Plus 400 and is the answer not in the manual?
Questions and answers
como calibrar pantalla
@Prisciliano Evangelista Evangelista Pablo
To calibrate the screen on an Allen-Bradley PanelView Plus 400:
1. Enter configuration mode.
2. Select: Terminal Settings > Touch Screen > Calibration.
3. Follow the on-screen instructions to touch the screen four times.
4. If the touches are not accurate, the system will request more until calibration is successful.
This answer is automatically generated