Download Print this page

Cisco MGX 8950 Installation Manual page 36

Hide thumbs Also See for MGX 8950:

Advertisement

Installation Procedures
Figure 3-19 Interconnect Cable for AC
Alignment key
The shrouds on the AC cables and the receptacles on the card cage and power trays are keyed to ensure
proper connections. Do not attempt to insert cables into shrouds that are not keyed for them.
Note
The AC power interconnect cables from each tray must be connected to the backplane. If the cables are
not connected, the power supply monitoring circuit will mistake this as voltage failure and will result in
a tripped circuit breaker.
You will need the following cables:
Cisco Systems part number 72-2420-XX
Cisco Systems part number 72-2421-XX
Cisco Systems part number 72-2422-XX
Cisco Systems part number 72-2423-XX
See
Table 3-2
cage and power trays:
Table 3-2
Cable Label
Card Cage A1
Card Cage B1
Card Cage B2
Card Cage A2
Cisco highly recommends that you install and use a redundant AC power supply.
Note
Perform the following procedure to install the interconnect connections for an AC-Powered
Cisco MGX 8950 switch with a redundant AC power supply:
Cisco MGX 8950 Hardware Installation Guide
3-36
To power
supply
(PS tray 1 J1)
and
Figure 3-20
for assistance with connecting the AC power tray connectors to the card
AC Power Cable Connections
Card Cage Connect
PSA 1
PSB 1
PSB 2
PSA 2
Cable Label
Power Tray Connector
PS Tray 1 J1
J1 on primary (top) PS Tray
PS Tray 2 J1
J1 on secondary (bottom) PS Tray
PS Tray 2 J2
J2 on secondary PS Tray
PS Tray 1 J2
J2 on primary PS Tray
Release 3, Part Number 78-14147-02 Rev. A0, November 2002
Chapter 3
Installing a Cisco MGX 8950
Alignment key
To card cage
(card cage A1)

Advertisement

loading