Alarm Cable & Button Installation
Cable Specification
BEAM cable should be used for installation of alert buttons, or cable that complies
with the following specification to ensure proper installation and use.
Up to 100 metres (300 feet) per loop
Use only medium duty polarised figure 8 cables with 19 conductors of 0.193mm or
better, for each alarm loop, to 100m in length.
Due consideration must be made on using cable with UV stable and/or flame -
retardant insulation where the installation requires it.
In excess of 100 metres (300 feet) per loop
The total maximum cable length for the loops 500 metres (1500 feet).
Use only heavy-duty polarised figure 8 cables with 24 conductors of 0.2mm or better,
for each alarm loop.
Due consideration must be made on using cable with UV stable and/or flame -
retardant insulation where the installation requires it.
The total maximum cable length for loops should still not exceed 500 metres (1500
feet)
Note: When installing cabling through a noisy electrical environment, it
is recommended to consider using a shielded type of the above
cables, and/or a twisted pair.