Emergency Event; Mergency State; Mergency State Sequence - Beam IridiTRAK RST430 Installation & User Manual

Alert / tracking / monitoring interface
Hide thumbs Also See for IridiTRAK RST430:
Table of Contents

Advertisement

IridiTRAK Installation & User Manual

Emergency Event

Emergency State:
The unit has one emergency state, irrelevant of what triggered the alarm. When
Emergency is turned ON, unit will not differentiate between Alarm button pressed
and Man down pendent; both will be treated as only one Emergency.
While unit is on emergency mode, unit will send Emergency messages.
Emergency state sequence:
When emergency is trigged the flowing event sequence will happen.
1. Emergency Triggered.
This could be done by either pressing Emergency button or by triggering the
man down pendent.
2. Alert LED is ON (not flashing)
On IridiTRAK Alert LED, indicates trying to send message.
3. Emergency Message sent by the unit to the server.
First message goes through IridiTRAK.
4. Alert LED is flashing slowly
On IridiTRAK Alert LED, this indicates at least one message has been sent.
5. E-mail will be delivered with attachment file from Iridium.
Open and read file using text editor or Hex Edit if sent in economy message
format.
6. Acknowledge needs to be sent to Unit from the server / control center.
Send remote command "LTK NOREP @<supervisor pin>
Refer page 29 "Reading MO Message from E-mail" for to get more information
on how to send message to unit
7. Alert LED flashing quickly.
On IridiTRAK Alert LED, this indicates at least one message has been
received and acknowledged by the server / control center.
8. IridiTRAK Unit continues to send a message at every Defined Time Interval.
(default 5 minutes)