Maximum charging current:
To configure the total
charging current for solar
02
and utility chargers.
(Max. charging current =
utility charging current +
solar charging current)
03
AC input voltage range
Power saving mode
04
enable/disable
05
Battery type
Automatically restart when
06
overload occurs
30A
50A
70A
90A
110A
130A (only for 3KVA
with MPPT models)
Appliances (default)
UPS
Saving mode disable
(default)
Saving mode enable
AGM (default)
User-Defined
Restart disable
(default)
14
40A
60A (default)
80A
100A
120A (only for 3KVA with MPPT
models)
140A (only for 3KVA with MPPT
models)
If selected, acceptable AC input
voltage range will be within
90-280VAC.
If selected, acceptable AC input
voltage range will be within
170-280VAC.
If disabled, no matter connected load
is low or high, the on/off status of
inverter output will not be effected.
If enabled, the output of inverter will
be off when connected load is pretty
low or not detected.
Flooded
If "User-Defined" is selected, battery
charge voltage and low DC cut-off
voltage can be set up in program 26,
27 and 29.
Restart enable