MPP Solar 2424LV-HS User Manual page 19

Pip 3kva/24v solar inverter charger 110/120v output
Table of Contents

Advertisement

20
Backlight control
Beeps while primary source
22
is interrupted
Overload bypass:
When enabled, the unit will
23
transfer to line mode if
overload occurs in battery
mode.
25
Record Fault code
Bulk charging voltage
26
(C.V voltage)
27
Floating charging voltage
29
Low DC cut-off voltage
Solar power balance:
When enabled, solar input
31
power will be automatically
adjusted according to the
connected load power.
Backlight on (default)
Alarm on (default)
Bypass disable
(default)
Record enable
default setting: 28.2V
If self-defined is selected in program 5, this program can be
set up. Setting range is from 24.0V to 29.2V. Increment of
each click is 0.1V.
default setting: 27.0V
If self-defined is selected in program 5, this program can be
set up. Setting range is from 24.0V to 29.2V. Increment of
each click is 0.1V.
default setting: 21.0V
If self-defined is selected in program 5, this program can be
set up. Setting range is from 20.0V to 24.0V. Increment of
each click is 0.1V. Low DC cut-off voltage will be fixed to
setting value no matter what percentage of load is connected.
Solar power balance
enable (Default):
Solar power balance
disable:
17
Backlight off
Alarm off
Bypass enable
Record disable (default)
If selected, solar input power will
be automatically adjusted
according to the following formula:
Max. input solar power = Max.
battery charging power +
Connected load power.
If selected, the solar input power
will be the same as max. battery
charging power no matter how
many loads are connected. The
max. battery charging power will
be based on the setting current in
program 02.
(Max. solar power = Max. battery
charging power)