Ethernet Connection; Receiver Ethernet Settings; View Receiver Ip Addresses - Topcon MR-2 Operator's Manual

Table of Contents

Advertisement

8. If using a secondary receiver board, select the Secondary Receiver check box, and select Serial C from
the Receiver Port drop-down list (Figure 18 on page 21).
9. Click Connect to establish a connection.
Once the receiver connects to TRU, the icons on the main screen become active. Once active, you can configure
the receiver.

Ethernet Connection

This section describes how to customize the Ethernet settings in the receiver, and how to connect to the receiver
with TRU using an Ethernet connection.

Receiver Ethernet Settings

To verify Ethernet connectivity, the receiver must be connected to an external network or laptop. For a laptop
connection, set up a static IP address on the computer.
Once connected, the Ethernet LED will be solid 2-5 seconds after the receiver is powered on, indicating that an
Ethernet connection is established. If the Ethernet LED does not become green after 10 seconds, check the
external network connect, or reboot the receiver.

View Receiver IP Addresses

The receiver contains a main and auxiliary GNSS board. The IP address for the main board is 192.168.0.9 and
the IP address for the auxiliary board is 192.168.0.10.
To view the IP address of each board, do the following.
1. Connect the receiver to TRU using a Serial connection. See "Connect The Receiver to TRU" on page 20.
2. In TRU, click Receiver SettingsNetwork. The Network screen appears and the Ethernet tab is
active (Figure 20).
3. Write down the IP Address and Gateway.
Ethernet Connection
Figure 20: TRU – Network Screen
P/N: 1011907-01