Setting Time of Day & Initiating a Manual Regeneration
Setting the Time of Day:
To set the time of day, push the red button and spin the 24-hour gear until the present time of day is
visible above the time of day arrow.
Forcing a Manual Regeneration:
To manually regenerate the valve, turn the manual regeneration knob clockwise until it reads
"REGEN."
Setting the Time of Day:
To set the time of day, push the red button and spin the 24-hour gear until the present time of day is
visible above the time of day arrow.
Setting the Program Wheel:
To set the program wheel, lift the "people" dial and rotate it so that the number of people in the
household is aligned with the household grains per gallon water hardness. Release the dial and
check for firm alignment at the setting. This provides reserve capacity based on 75 gallons per
person.
Forcing a Manual Regeneration:
To manually regenerate valve, turn the manual regeneration knob clockwise until it reads "REGEN."
NOTE: Unit will regenerate tonight when the gallon capacity reaches zero.