Fan Speed For Manual Mode; Pressure For Manual Mode; Flow Rate For Manual Mode; Fresh Air Proportion For Manual Mode - Wolf WRS-K Installation And Operating Instructions Manual

Regulatory system
Table of Contents

Advertisement

Fan speed for manual mode

STANDARD SETTING
Ventilation air speed
for manual mode
020 %
Esc BACK
SELECTION

Pressure for manual mode

STANDARD SETTING
Vent. air fan pressure
set value for
manual mode
0750.0 Pa
Esc BACK
SELECTION

Flow rate for manual mode

STANDARD SETTING
Vent. air flow rate
set value for
manual mode
001500 m
Esc BACK
SELECTION
Fresh air proportion for
manual mode
STANDARD SETTING
Prop. fresh air
for manual mode
060 %
Esc BACK
SELECTION

Speed for external demand

STANDARD SETTING
Vent. air speed for
external demand
Stage 3:
Stage 2:
Stage 1:
Esc BACK
SELECTION

Pressure for external demand

STANDARD SETTING
Vent. air pressure for
external demand
Stage 3:
300 Pa
Stage 2:
200 Pa
Stage 1:
100 Pa
Esc BACK
SELECTION
3062878_201707
9. Operating level 1
Pressing
0.1 %. Finally confirm the selected value with
GE-03
For ventilation systems, the pressure figures for ventilation and extract air are
changed separately.
Please note The selected fan speed only applies in manual mode.
DISPLAY
Pressing
Finally confirm the selected value with
GE-05
For ventilation systems, the fan pressure for ventilation and extract air are changed
separately.
Please note The selected set pressure only applies in manual mode.
DISPLAY
Pressing
highlights the set flow rate that can then be changed with
Finally confirm the selected value with
GE-07
For ventilation systems, the set flow rates for ventilation and extract air are changed
separately.
Please note The selected set flow rate only applies in manual mode.
/h
3
DISPLAY
Pressing
the
keys. Finally confirm the selected value with
GE-09
Please note The selected set fresh air proportion only applies to manual mode.
DISPLAY
Pressing
Finally confirm the selected value with
GE-10
For ventilation systems, the speeds for supply and extract air for external demand are
changed separately.
100.0 %
060.0 %
030.0 %
DISPLAY
Pressing
Finally confirm the selected value with
GE-12
For ventilation systems, the pressures for supply and extract air for external demand
are changed separately.
DISPLAY
highlights the fan speed that can then be changed with
highlights the set pressure that can then be changed with
highlights the fresh air proportion that can then be adjusted in steps with
highlights the speed that can then be changed with
highlights the set pressure that can then be changed with
.
.
.
.
.
.
in steps of
.
.
.
.
17