Operating Level 1; Menu Structure; Main Menu - Wolf WRS-K Installation And Operating Instructions Manual

Regulatory system
Table of Contents

Advertisement

9.1. Menu structure, operating level 1
Only those menu points are shown that are relevant to the system concerned.
Prg
Operating data
Extract air/
set room temperature
Set temp transducer
Room temperature
Extract air temp
Set temp, vent. air
Vent. air temperature
Set value room/
extract air humidity
Set value, vent air rh
Rel. humidity (room)
Rel. hum., extract air
Rel. hum., vent. air
Pressure
Flow rate
Proportion fresh air
Sensors
Room temperature
Rel. humidity (room)
Vent. air temperature
Rel. hum., vent. air
Extract air temp
Rel. hum., extract air
Outside temperature
Icing-up temp
Outside temperature, day
Outside temperature, total
Air quality
Air pressure
Flow rate
Set value transducer
High pressure, refrigerant circuit 1 *
High pressure, refrigerant circuit 2 *
Low pressure, refrigerant circuit 1 *
Low pressure, refrigerant circuit 2 *
Boiler water temperature
3062878_201707

9. Operating level 1

Standard mask
Standard settings
Temperature manual mode
Fan stage/
enable manual mode
Fan speed manual mode
Pressure manual mode
Flow rate manual mode
Fresh air manual mode
Speed for ext. demand
Pressure for ext. demand
Flow rate for ext. demand
Automatic start via external
demand YES/NO
Set value, humidity
7-day program
YES/NO
Backup mode, heating
YES/NO
Backup mode, cooling
YES/NO
Mixed air damper operating
mode
Natural cooling
YES/NO
Night ventilation
YES/NO
Ext. utilisation time
YES/NO
Peak ventilation
YES/NO
Air quality control
YES/NO
Air quality control
YES/NO
Hygrostat function
YES/NO
Continuous hygrostat function
YES/NO
Quick heating
ON/OFF
* Available only
when there is
communication with
IK Control via pLan
Esc

Main menu

Standard settings
Displays
Time functions
Contractor
Displays
Sensors
Components
Hours run
Other...
Components
Fan stage
Fan speed
Pump, heating circuit
Heating water pump
Heating water valve
Pump, cooling circuit
Cold water pump
Cold water valve
Direct evaporator
Heat pump
Electric heater bank
Electric heater bank
Direct evaporator
No reheater bank
Mixer air damper
Heat recovery
Last filter check
Humidifier
Ext. enabling
KGWO
No reheater bank
Set boiler temperature
See page 20
Password
1234
Time functions
7-day program
Day program
Set values
Holiday program
Date/time
Hours run
Others
Total system
Software version
Fans
System configuration
Language selection
Heat pump
15