Application Controfix; Contents Of Delivery - Kessel Staufix SWA Installation And Operating Manual

Backwater valve for wastewater with or without sewage, clean-out
Table of Contents

Advertisement

Dear Customer,
Before installing and commissioning this
KESSEL Staufix® SWA or Controfix® ,
please thoroughly read through this ma-
nual and follow all instructions!
Please make sure that nothing was dama-
ged during the shipment of this item. In case
damage did occur during the shipment plea-
se go to Section 5 - Guarantee
1.1 Application of the Staufix
The KESSEL Staufix® SWA backwater valve
is designed to be installed in wastewater drai-
nage pipes with or without raw sewage. The
backwater valve prevents wastewater from
backing up the drainage pipe during backwa-
ter / flooding. The SWA should be kept in good
operating condition and should be accessible
at all times. During normal conditions the back-
water flap is in the vertical, free handing posi-
tion. Wastewater draining out of the building
pushes the flap open and is allowed to flow
through the SWA and out of the building. The
SWA is equipped with a manual flap locking
valve which can be used to fully lock the flap
shut – allowing no wastewater in either direc-
tion to pass through the valve. In the case that
the drainage pipes connected to the Staufix®
SWA will not be used over extended periods of
time it is recommended that the flap is secure-
ly locked with the locking lever. Important is
that when the wastewater pipes return to ser-
vice that the flap is unlocked. DIN EN 12056
and DIN EN 13564 should be followed which
regulated the drainage of building and use of
®
SW
backwater valves.
1.2 Application Controfix®
The KESSEL Controfix® serves as the body
housing for all KESSEL Staufix® and Pumpfix
series backwater valves. The following instal-
lation instructions should be heeded. Since the
KESSEL Controfix® serves as a cleanout or
access to the drainage piping, the Controfix®
does not contain any backwater flaps and thus
does not offer any protection against backwa-
ter. Upgrade packages are available that can
1. General
23
be used to upgrade the Controfix® to any
KESSEL Staufix® or Pumpfix backwater val-
ves.

1.3 Contents of Delivery

The Staufix® SWA delivery consists of a body
/ housing with cover including the emergency
closure lever (closure lever not included with a
Controfix® ), and installation and operating
manual (Article Number 010-841) and a see-
thru test funnel used for testing the valve after
installation (test funnel not included with a
Controfix® ).