Instructions Somfy Solar Rain Sensor (SRS) - RTS
IMPORTANT - Read the entire instructions and ensure the unit is charged before starting installation (see installation section)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions
- This device may not cause harmful interference and
- This device must accept any interference received, including interference that may cause undesired operation
Warning! Changes or modifications not expressly approved by the manufacturer could void the users authority to operate the equipment.
1 - Open the hatch by pressing the latch toward the hatch and pulling outward (Fig 1)
2 - Inside the hatch you will see the Rain and Sun threshold adjustment pots, the DEMO and
Program Buttons and the Mode Dip Switches (Fig 2).
3 - Do not remove the sticker over dip switches 3 and 4. Only Dip switches 1 and 2 will be
used to select the Mode for normal Awning use.
4 - Select the desired mode using dip switches 1 and 2. Dips 3 and 4 should remain off.
ON
ON
A
A
1
1
2
2
3
3
4
4
Awning Rain
Awning Rain
5 - In Awning Rain mode (A), the SRS will run the awning in when the rain rate exceeds
the set rain threshold.
6 - In Awning Sun mode* (B), the SRS will run the awning in after about 15-30 min with the
sun below the set sun threshold and out after about 2 min with the sun above the threshold.
7 - In Awning Rain & Sun mode* (C), the rain and sun functions are both active but a rain
event will override the sun function until the rain rate falls below the set threshold for 5 min.
8 - The Sun and Rain threshold adjustment pots can be turned 280 deg from the minimum
setting to the maximum. (Fig 3)
9 - The Rain threshold (Fig 4) can be set from:
Min (fully CCW) = Very Light Rain/Heavy Mist/Heavy Condensation
Max (fully CW) = Very Heavy Rain.
10 - The Sun threshold (Fig 5) can be set from
Min (fully CCW) = approx 0.5klux - Facing sun with heavy cloud cover
Max (Fully CW) = approx 55klux - Facing direct summer sun with no cloud cover
11- LED indicators, The rain and sun LEDs will blink when conditions are above the
threshold, continuously in DEMO mode and every 5 sec in normal mode.
Note; In order for the SRS to activate a motor in response to sun, the sun function of the motor
must be enabled. To enable this feature, a Soliris Transmitter must be used and therefore
programmed to the motor.
Factory Default settings:
Important: If the RTS Rain and Sun sensor is removed from a job site it must be deleted from the motor memory.
(see next section)
2.088"
[53.04]
4.479"
[113.77]
Mode and Threshold Selection - Awning
ON
ON
B
B
2
2
1
1
3
3
4
4
Awning Sun
Awning Sun
ON
ON
A
A
2
2
1
1
3
3
4
4
Awning Rain
Awning Rain
ON
ON
C
C
1
1
2
2
3
3
4
4
Awning Rain & Sun
-
-
-
-
+
+
Min Max
Min Max
Min
Min
RAIN
RAIN
Approx 12:00
Approx 12:00
Approx 9:00
Approx 9:00
Facing Sun, Light Cloud Cover
Facing Sun, Light Cloud Cover
Light Rain
Light Rain
2.590"
[65.79]
Latch
Latch
Hatch
Hatch
Sun LED
Sun LED
Rain LED
Rain LED
Fig 1
Fig 1
RAIN
RAIN
SUN
SUN
ON
ON
PROG
PROG
DEMO
DEMO
1
1
2
2
3
3
4
4
Fig 2
Fig 2
Sticker
Sticker
POT
POT
Adj
Adj
Range
Range
-
-
-
-
+
+
Min Max
Min Max
Min
Min
-
-
+
+
RAIN
RAIN
SUN
SUN
Max
Max
Min
Min
280 deg
280 deg
Fig 4
Fig 4
Fig 5
Fig 5
Fig 3
Fig 3
+
+
Max
Max
SUN
SUN
+
+
Max
Max

Advertisement

loading

Summary of Contents for SOMFY RTS

  • Page 1 Approx 9:00 Facing Sun, Light Cloud Cover Facing Sun, Light Cloud Cover Light Rain Light Rain Important: If the RTS Rain and Sun sensor is removed from a job site it must be deleted from the motor memory. (see next section)
  • Page 2 Min Max RAIN Approx 12:00 Approx 9:00 Awning Rain Facing Sun, Light Cloud Cover Light Rain Important: If the RTS Rain and Sun sensor is removed from a job site it must be deleted from the motor memory. (see next section)
  • Page 3 LEDs will blink every 5 sec if conditions are above the threshold. Installation - Initial Charge - The Somfy Solar Rain Sensor (SRS) RTS is solar powered. Before installation ensure the unit has an initial charge by placing the unit with the solar cell facing direct sun light.