READ A SETUP BARCODE

CONFIGURE PARAMETERS

For most of the scanner parameters, only one read is required to set them to new values.
The scanner will respond with two beeps (low-high tone) when each parameter is set
successfully.
But for a number of special parameters, multiple reads are required to complete the
setting. In this case, the scanner will respond with a short beep indicating it needs to
read more setup barcodes. These special parameters may require reading one or more
setup barcodes, such as
Numeric barcodes, say, for keyboard type, inter-character delay, length qualification
Hexadecimal barcodes, say, for character strings as prefix, suffix, etc.
When "Keyboard Wedge" or "USB HID" is configured as the interface, Key Type and
Key Status will then become applicable. Decide whether or not to change key status
when "Normal Key" is selected for Key Type.
To complete the configuration of these special parameters, it requires reading the
"Validate" barcode, and then the scanner will respond with two beeps (low-high tone) to
indicate the input values are validated.