Endress+Hauser Proline Prowirl F 200 Operating Instructions Manual page 154

Profibus pa vortex flowmeter
Hide thumbs Also See for Proline Prowirl F 200:
Table of Contents

Advertisement

Technical data
Low flow cut off
Galvanic isolation
Protocol-specific data
154
Type of protection Ex ic
Order code for "Output"
Option G
IS type of protection
Order code for "Output"
Option G
The switch points for low flow cut off are user-selectable.
All outputs are galvanically isolated from one another.
PROFIBUS PA
Manufacturer ID
Ident number
Profile version
Device description files (GSD,
DTM, DD)
Output values
(from measuring device to
automation system)
Output type
PROFIBUS PA
Pulse/frequency/switch output
Output type
PROFIBUS PA
Pulse/frequency/switch output
0x11
0x1564
3.02
Information and files under:
www.endress.com
www.profibus.org
Analog input 1 to 4
• Mass flow
• Volume flow
• Corrected volume flow
• Density
• Reference density
• Temperature
Digital input 1 to 2
• Status
• Low flow cut off
• Switch output
Totalizer 1 to 3
• Mass flow
• Volume flow
• Corrected volume flow
Proline Prowirl F 200 PROFIBUS PA
Intrinsically safe values
STANDARD
FISCO
U
= 32 V
U
= 17.5 V
i
i
l
= 300 mA
l
= n.a.
i
i
P
= n.a.
P
= n.a.
i
i
L
= 10 µH
L
= 10 µH
i
i
C
= 5 nF
C
= 5 nF
i
i
U
= 35 V
i
l
= 300 mA
i
P
= 1 W
i
L
= 0 µH
i
C
= 6 nF
i
Intrinsically safe values
STANDARD
FISCO
U
= 30 V
U
= 17.5 V
i
i
l
= 300 mA
l
= 550 mA
i
i
P
= 1.2 W
P
= 5.5 W
i
i
L
= 10 µH
L
= 10 µH
i
i
C
= 5 nF
C
= 5 nF
i
i
U
= 30 V
i
l
= 300 mA
i
P
= 1 W
i
L
= 0 µH
i
C
= 6 nF
i
Endress+Hauser

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Proline Prowirl F 200 and is the answer not in the manual?

Table of Contents

Save PDF