Peristaltic Cased Tube Pumps
Operating Manual
Version
3.4v-01/2019
Print-No.
01
Verderflex Vantage 3000 P
EZ / S10 / R3i

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vantage 3000 P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Verderflex Vantage 3000 P

  • Page 1 Peristaltic Cased Tube Pumps Operating Manual Verderflex Vantage 3000 P EZ / S10 / R3i Version 3.4v-01/2019 Print-No.
  • Page 2 EZ / S10 / R3i The information in this document is essential for the safe operation and servicing of Verderflex Vantage 3000 pumps. This document must be read and understood thoroughly prior to installation of unit, electrical connection and commissioning.
  • Page 3: Table Of Contents

    8.18 IP66 Remote Speed Control 8.19 Pause Function Software Installation Menu Tree 10.1 Save Settings 10.2 Reload Settings Remote Interface 11.1 Manual Mode 11.2 Memo-Dose Mode 11.3 Dose Mode 11.4 Batch Mode Vantage 3000 P Version 3.4v-01/2019 3 | Page...
  • Page 4: Keypad Keys, Symbols And Key Combinations

    MAX then press DOSE Speed Ramp OFF/ON Press and hold down UP then press RPM Save Dose settings Press and hold down UP then press DOSE Table 2 Keypad Key Combinations Vantage 3000 P Version 3.4v-01/2019 4 | Page...
  • Page 5: Key Features

    30/ EU as well as Machine Directive 2006/42/EC. rates with a quick and easy setup. Vantage 3000 P is a programmable, easy tube load pump with Installation of this pump into other equipment must a stackable pump head and requires low maintenance.
  • Page 6: Maintenance

    7 Installation Pump should be installed by suitably qualified personnel Pump should be sited on stable horizontal surface Allow free flow of air around pump Tube should not be allowed to kink. Vantage 3000 P Version 3.4v-01/2019 6 | Page...
  • Page 7: Types Of Pump Head

    7.1 Types of Pump Head Verderflex Vantage 3000 P pumps are available with the S10 pump head featured on the Verderflex Smart tube pump, ® as well as the R3i head featured on the Verderflex Rapide tube pump providing greater flow rates with stackable and multi channel head options.
  • Page 8: Replacing The Pump Head

    3. Push twist unit location lever clicks into position. 4. Remove depressing location lever stackable head twisting pump head counter clockwise 45°. Location lever Table 6 Stacking – EZ Head Vantage 3000 P Version 3.4v-01/2019 8 | Page...
  • Page 9: S10 Head

    3. Open up the lever and fit the claw over 4. Push the lever down to lock the saddle into place over the other set of dowels Table 7 Installing Tube – S10 Head Vantage 3000 P Version 3.4v-01/2019 9 | Page...
  • Page 10: R3I Head

    2. Align peak of roller with peak of tube track or set rotor distance back from front of pump housing 3. Fasten grub screw securely Fastening grub screw Table 9 Replacing the Rotor – R3i Head Vantage 3000 P Version 3.4v-01/2019 10 | Page...
  • Page 11: Functions

    100 RPM 80 525ML/MN 250 RPM8 0 1313ML/MN 150 RPM 80 788ML/MN 150 RPM 80 788ML/MN Updating Tube Size 100 RPM 80 525ML/MN 100 RPM 525ML/MN 100 RPM 525ML/MN 100 RPM 48 525ML/MN Vantage 3000 P Version 3.4v-01/2019 11 | Page...
  • Page 12: Adjust Pump Speed

    ---M L/MN 050.0 ML >>0 25.0 ML • Press dose button and then run the pump to check 100 RPM 80 ---M L/MN measured dose. 050.0 ML >>0 25.0 ML Pump calibrated Vantage 3000 P Version 3.4v-01/2019 12 | Page...
  • Page 13: Recall Saved Calibration

    Press dose button twice (you 050.0 ML >>0 25.0 ML are now back to home screen). 100 RPM 80 525M L/MN 050.0 ML >>0 25.0 ML 100 RPM 80 525ML/MN Exit Calibration Vantage 3000 P Version 3.4v-01/2019 13 | Page...
  • Page 14: Runback (Anti-Drip)

    100 RPM 80 525ML/MN 8.7 Maximum Function Feature 100 RPM 80 525ML/MN 100 RPM 80 525ML/MN 100 RPM 80 525ML/MN 250 RPM 80 1313ML/MN 250 RPM 80 1313ML/MN 250 RPM 80 1313ML/MN Vantage 3000 P Version 3.4v-01/2019 14 | Page...
  • Page 15: Single Dose Function

    262.5 ML 000.0 S INT 100 RPM 80 525ML/MN 262.5 ML 000.0 S INT Speed RAMP Function 150R PM 80 525ML/MN RAMP 80 525ML/MN 80 525ML/MN Exit RAMP 80 525ML/MN Function 80 5 25ML/MN Vantage 3000 P Version 3.4v-01/2019 15 | Page...
  • Page 16: Multi Cyclic Dosing

    Note: Dose and Max button has to be pressed together, at the same BATCH time to activate Batch function. 050.0M L 0 02.0 S INT 100 RPM 80 525ML/MN 050.0M L 0 02.0 S INT Exit Function Vantage 3000 P Version 3.4v-01/2019 16 | Page...
  • Page 17: Save Dose Settings To Prog

    100 RPM 48 235ML/MN 100 RPM 48 235ML/MN 8.13 Save Dose Settings to 150.0M L 002.0 S INT PROG 2 - 10 PROG1 OIL1 PROG7 AAAA Continued same as for PROG 1 Vantage 3000 P Version 3.4v-01/2019 17 | Page...
  • Page 18: Recall Saved Dose Setting

    100 RPM 80 525ML/MN 100 RPM 80 525ML/MN 100 RPM MD 525ML/MN Dosing period for previous dosing saved (0.5 Sec) 100 RPM MD 525ML/MN Repeat memory dose Exit Function 100 RPM 80 525ML/MN (0.5 Sec) Vantage 3000 P Version 3.4v-01/2019 18 | Page...
  • Page 19: Keypad Lock Function

    Stopped CCW pump running +5V out pump stopped +5V out pump running GND pump stopped GND IP 66 Remote Speed control speed control 0-10V d.c 10K (0.5W) Table 10 Analogue /Digital Remote Interface Vantage 3000 P Version 3.4v-01/2019 19 | Page...
  • Page 20: Ip66 Remote Speed Control

    The PAUSE function can be activated when the pump is running. PPP RPM 80 PPPP ML/MN PPPPPML PPPPP S INT PUMP PAUSED 100 RPM 80 525ML/MN 050.0M L 0 02.0 S INT 100 RPM 80 525ML/MN Vantage 3000 P Version 3.4v-01/2019 20 | Page...
  • Page 21: Software Installation

    Software Installation Insert installation disc open  “My computer” from start menu Click and open CD/DVD drive  Copy and paste “PCPUMP.exe” onto the  desktop or into preferred folder Vantage 3000 P Version 3.4v-01/2019 21 | Page...
  • Page 22: Menu Tree

    Run “PCPUMP.exe”  10 Menu Tree Normal Dose Batch Calibrate Speed control . . . Runback Speed Ramp Use calibration Vantage 3000 P Version 3.4v-01/2019 22 | Page...
  • Page 23 Normal Speed control . . . Dose Runback Calibrate Use calibration Vantage 3000 P Version 3.4v-01/2019 23 | Page...
  • Page 24: Save Settings

    10.1 Save Settings 10.2 Reload Settings Vantage 3000 P Version 3.4v-01/2019 24 | Page...
  • Page 25: Remote Interface

    *(Please Note: Keypad operation has priority over the remote interface) (3: TURN ON PUMP) (2: INSTALL PC PUMP PROGRAM) NULL MODEMRS232 (IP66) (1: INSERT DISC) IP 66 SOFTWARE BUNDLE PROGRAMMABLE DISPENSER Figure 3 IP66 Computer Control Vantage 3000 P Version 3.4v-01/2019 25 | Page...
  • Page 26 RS232 control 12.2 Layout of Back Plate Figure 4 Back Plate – Vantage 3000 C Figure 5 Back Plate – Vantage 3000 P 12.3 External Controls on Different Models The control methods featured on each model are as listed below:...
  • Page 27 Foot switches can be used to remotely turn the pump on and off, freeing the hands to perform other operations or providing ergonomic improvement at a workstation. Footswitch Vantage 3000 25 way “D” connector Figure 7 Connecting the Footswitch Vantage 3000 P Version 3.4v-01/2019 27 | Page 27 | Page...
  • Page 28 10 on the 25way “D” connector and pin 11 as a 0 – 5 volt input as shown in Table 10. Variable Voltage/Current source Vantage 3000 25 way “D” connector Figure 8 Connecting Variable Voltage/Current Source Vantage 3000 P Version 3.4v-01/2019 28 | Page 28 | Page...
  • Page 29 Counter Clockwise Started CCW Stopped CCW IP 66 Remote speed control Speed control 0-10V d.c Potentiometer 4-20mA Table 14 Pin Connection for Analogue Control (refer table 2 for pin description) Vantage 3000 P Version 3.4v-01/2019 29 | Page 29 | Page...
  • Page 30 12.7 Foot /Hand Switch Control Verderflex Vantage 3000 pump model “P” has an RS232 computer interface for communication with process controllers and Verder- flex PC windows user software. The pump can be connected to a PC/Laptop using a Null Modem serial cable and/or a USB/RS232 convertor.
  • Page 31 Click on the file PCpump.ini in your Windows root directory and edit the line “Port=xx” where xx = the port number you recorded earlier. E.g. Port=04. Save the edited file. Figure 13 Opening “Device Manager” Vantage 3000 P Version 3.4v-01/2019 31 | Page 31 | Page...
  • Page 32 Figure 14 Opening “ Port Settings” PC pump Serial interface.doc contains information for the control of the pump using ASCII code character strings. (Communications protocol) Dated 01/09/2013 Figure 15 Opening “USB Serial Port Settings” Vantage 3000 P Version 3.4v-01/2019 32 | Page 32 | Page...
  • Page 33 25 way ‘D’ Type Connector (Remote Control Lead P/N: AU E1973) 8.17 Figure 3 IP66 Computer Control 11.2 Figure 4 Back Plate – Vantage 3000 P 12.2 Figure 5 Back Plate – Vantage 3000 P 12.2 Figure 6 25 Way ‘D’ Type Connector 12.4...
  • Page 34 EC declaration of conformity according to machine directive, appendix II A VERDER Ltd., Unit 3 California Drive, Castleford hereby declare that the following machine adheres to the relevant EC directives detailed below Designation Vantage 3000 P EZ Vantage 3000 P S10 Vantage 3000 P R3i EC directives: •...
  • Page 35 Sound pressure level is measured by the responsible body at both operators position in normal use and at whatever point 1.0m from the enclosure of the equipment that has the highest sound pressure rating. Vantage 3000 P Version 3.4v-01/2019 35 | Page...