Summary of Contents for Verderflex Vantage 3000 B

  • Page 1 Peristaltic Cased Tube Pumps Operating Manual Verderflex Vantage 3000 B Version 1.1v-01/2019 Print-No.
  • Page 2 Print-No. 01 The information in this document is essential for the safe operation and servicing of Verderflex Vantage 3000 pumps. This document must be read and understood thoroughly prior to installation of unit, electrical connection and commissioning. Vantage 3000 B EZ Version 1.1v-01/2019...
  • Page 3: Table Of Contents

    Warranty Pump Returns ‘EC’ Declaration Safety Intended Use Prevention of Obvious Misuse Maintenance Installation Installing the Tube Replacing the Pump Head Operating the Pump Declaration of Conformity Appendix - Pump Specifications Vantage 3000 B EZ Version 1.1v-01/2019 3 | Page...
  • Page 4: Key Features

    The manufacturer does not accept any liability for accurate and repeatable flow rates with a quick and damage resulting from disregard of this documentation. easy setup. Vantage 3000 B EZ is a manual control, 5.1 Intended Use easy tube load pump with a stackable pump head and requires low maintenance.
  • Page 5: Maintenance

    Pump should be installed by suitably qualified personnel Pump should be sited on stable horizontal surface Allow free flow of air around pump Tube should not be allowed to kink. Vantage 3000 B EZ Version 1.1v-01/2019 5 | Page...
  • Page 6: Installing The Tube

    Push and twist until location lever clicks into position. Remove by depressing location lever and Location lugs twisting pump head counter clockwise 45°. Table 2 Replacing Pump Head – EZ Head Vantage 3000 B EZ Version 1.1v-01/2019 6 | Page...
  • Page 7: Operating The Pump

    Clockwise and switch on the rotor For Counter clockwise rotation, set to Counter clockwise and switch on the rotor Press fast prime for momentary maximum speed. Table 3 Operating the Pump Vantage 3000 B EZ Version 1.1v-01/2019 7 | Page...
  • Page 8: Declaration Of Conformity

    EC declaration of conformity according to machine directive, appendix II A VERDER Ltd., Unit 3 California Drive, Castleford hereby declare that the following machine adheres to the relevant EC directives detailed below Designation Vantage 3000 B EZ EC directives: • Machine Directive (2006/42/EC) • Low-voltage directive (2014/35/EU) •...
  • Page 9: 10 Appendix Pump Specifications

    Sound pressure level is measured by the responsible body at both operators position in normal use and at whatever point 1.0m from the enclosure of the equipment that has the highest sound pressure rating. Vantage 3000 B EZ Version 1.1v-01/2019 9 | Page...