Remote Sequence Selection
The active sequence can be changed using Connector
#1 (AP) on the ADM. Selection bits are pulled high by
default and must be dropped low to select the desired
sequence.
ADM Connector #1 (AP)
NOTE: The view shown looking at the pins on the end of the cable.
2
3
Sequence
Sequence
Sequence
Selection
Number
BIT0
Selected
(Conn. #1,
(Conn. #1,
Pin #1)
None /
Display
High
Module
Selection
1
Low
2
High
3
Low
4
High
5
Low
6
High
7
Low
8
High
9
Low
10
High
11
Low
12
High
13
Low
14
High
15
Low
3A6165A
1
Brown
5
Gray
4
Black
Blue
White
Sequence
Sequence
Selection
Selection
Selection
BIT1
BIT2
(Conn. #1,
(Conn. #1,
Pin #2)
Pin #4)
High
High
High
High
Low
High
Low
High
High
Low
High
Low
Low
Low
Low
Low
High
High
High
High
Low
High
Low
High
High
Low
High
Low
Low
Low
Low
Low
SHOT SEL - BIT 0
SHOT SEL - BIT 3
SHOT SEL - BIT 2
COMMON
SHOT SEL - BIT 1
BIT3
Pin #5)
High
High
High
High
High
High
High
High
Low
Low
Low
Low
Low
Low
Low
Low
ADM Screen Overview