Allen-Bradley ArmorBlock EtherNet/IP 1732E-OB16M12R Installation Instructions Manual

Allen-Bradley ArmorBlock EtherNet/IP 1732E-OB16M12R Installation Instructions Manual

2-port module
Hide thumbs Also See for ArmorBlock EtherNet/IP 1732E-OB16M12R:

Advertisement

Installation Instructions
ArmorBlock 2-Port EtherNet/IP Module
Catalog Numbers 1732E-IB16M12R, 1732E-OB16M12R,
1732E-IB16M12DR, 1732E-OB16M12DR, 1732E-16CFGM12R,
1732E-IB16M12SOEDR, 1732E-8X8M12DR

Table of Contents

Topic
Page
2
3
3
4
6
6
6
7
8
9
12
13
15

Advertisement

Table of Contents
loading

Summary of Contents for Allen-Bradley ArmorBlock EtherNet/IP 1732E-OB16M12R

  • Page 1: Table Of Contents

    Installation Instructions ArmorBlock 2-Port EtherNet/IP Module Catalog Numbers 1732E-IB16M12R, 1732E-OB16M12R, 1732E-IB16M12DR, 1732E-OB16M12DR, 1732E-16CFGM12R, 1732E-IB16M12SOEDR, 1732E-8X8M12DR Table of Contents Topic Page Important User Information Environment and Enclosure Preventing Electrostatic Discharge Overview Catalog Number Explanation Install the Module Set the Network Address Mount the Module Product Dimensions Connect the I/O, Network and Auxiliary Cables to the Module...
  • Page 2: Important User Information

    2 ArmorBlock 2-Port EtherNet/IP Module Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.rockwellautomation.com/literature/) describes some important differences between solid-state equipment and hard-wired electromechanical devices.
  • Page 3: Environment And Enclosure

    ArmorBlock 2-Port EtherNet/IP Module Environment and Enclosure ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating. This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR 11.
  • Page 4: Overview

    • download a free electronic version from the internet: http://www.rockwellautomation.com/literature/ • purchase a printed manual by contacting your local Allen-Bradley distributor or Rockwell Automation representative Overview The EtherNet/IP ArmorBlock is a 24V DC I/O module that communicates via EtherNet/IP. The sealed IP65, IP67 and IP69K housing of these modules requires no enclosure.
  • Page 5 ArmorBlock 2-Port EtherNet/IP Module Module Identification Status LEDs Functional Earth EtherNet/IP D-Code EtherNet/IP D-Code LINK 1 LINK 2 M12 connector M12 connector M12 I/O connectors M12 I/O connectors Node address Auxiliary power switches Protective Earth 44945 (1) Protective Earth is provided for the grounding of field devices and is internally connected to each Pin 5 of the M12 I/O connectors.
  • Page 6: Catalog Number Explanation

    6 ArmorBlock 2-Port EtherNet/IP Module Catalog Number Explanation Refer to the table for a description of the module catalog numbers. Catalog Number Description Network Auxiliary Connector Power 1732E-IB16M12R 16 Channel 24V DC Digital Input Dual-Port Dual D-code Single EtherNet Module 4-pin mini 1732E-OB16M12R 16 Channel 24V DC Digital Output Dual-Port...
  • Page 7: Mount The Module

    ArmorBlock 2-Port EtherNet/IP Module 2. Line up the small notch on the switch with the number setting you wish to use. Valid settings range from 001…254. 3. Cycle power. Set Network Address Example shows default node address set at 163. 44233 When the switches are set to a valid number, the I/O block’s IP address is 192.168.1.xxx (where xxx represents the number set on the switches).
  • Page 8: Product Dimensions

    8 ArmorBlock 2-Port EtherNet/IP Module Product Dimensions Refer to the mounting dimensions illustration to help you mount the module. Module Dimensions 43.25 mm 65 mm (1.70 in.) (2.56 in.) 26.5 mm (1.04 in.) LINK 1 LINK 2 179 mm (7.05 in.) 169 mm (6.65 in.) 44946...
  • Page 9: Connect The I/O, Network And Auxiliary Cables To The Module

    ArmorBlock 2-Port EtherNet/IP Module High Vibration Area Mounting Lock washer Flat washer 44766 Connect the I/O, Network and Auxiliary Cables to the Module The ArmorBlock EtherNet/IP family has 5-pin micro-style connectors. We provide caps to cover the unused connectors on your module. Connect the quick-disconnect cord sets you selected for your module to the appropriate ports.
  • Page 10 10 ArmorBlock 2-Port EtherNet/IP Module Self-configuring Connector (View into connector) Pin 1 Sensor source voltage Pin 2 Input or output B Pin 3 Return Pin 4 Input or output A Pin 5 PE 44807 I/O Self-configure Circuitry Turn output on Output circuit From PLC...
  • Page 11 ArmorBlock 2-Port EtherNet/IP Module Use the 1585D–M4DC–H: Polyamide small body unshielded or the IMPORTANT 1585D–M4DC–SH: Zinc die-cast large body shielded mating connectors for the D-Code M12 female network connector. Use two twisted pair CAT5E UTP or STP cables. IMPORTANT D-Code Wire color Signal 8-way modular...
  • Page 12: Configure The Module

    E-stop through the use of special E-stop drop or power T-ports and shorting plugs. Allen-Bradley E-stop T-ports and shorting plugs are red in color for easy identification.
  • Page 13: Interpret Led Indicators

    ArmorBlock 2-Port EtherNet/IP Module Refer to On-Machine Connectivity Catalog, publication M117-CA001, for Rockwell Automation cable and cord set offerings or use the configuration tools available at www.rockwellautomation.com/en/e-tools/. Interpret LED Indicators This module has the following indicators: • Network, Module, and Link status indicators for EtherNet/IP •...
  • Page 14 14 ArmorBlock 2-Port EtherNet/IP Module Indicator Status for Modules Indicator Status Description Module status No power applied to device. Flashing red/green The module is performing POST (Power-On Self Test), which completes within 30 s. Green Device operating normally. Flashing red Recoverable fault.
  • Page 15: Specifications

    ArmorBlock 2-Port EtherNet/IP Module Specifications 1732E ArmorBlock 2-Port EtherNet Module Input – 1732E-8X8M12DR, 1732E-IB16M12R, 1732E-IB16M12DR, 1732E-IB16M12SOEDR, 1732E-16CFGM12R Attribute Value Number of inputs 8 – 1732E-8X8M12DR 16 – all other modules Input type Sink, 24V DC Voltage, off-state input, max 5V DC Voltage, on-state input, max 30V DC Voltage, on-state input, nom...
  • Page 16 16 ArmorBlock 2-Port EtherNet/IP Module 1732E ArmorBlock 2-Port EtherNet Module Output – 1732E-8X8M12DR, 1732E-OB16M12R, 1732E-OB16M12DR, 1732E-16CFGM12R Attribute Value Voltage, on-state output, nom 24V DC Current on-state output, max 2.0 A – 1732E-OB16M12R 0.5 A – all other modules Current per module, max 4.0 A –...
  • Page 17 ArmorBlock 2-Port EtherNet/IP Module General Specifications Attribute Value Isolation voltage 50V (continuous), Basic Insulation Type, Inputs and Sensor Power to Network No isolation between individual Inputs or between Network channels Type tested at 707V DC for 60 s Status indicators Module status - red/green Network status - red/green Link status - green/yellow...
  • Page 18 18 ArmorBlock 2-Port EtherNet/IP Module Environmental Specifications Attribute Value Shock, non-operating IEC 60068-2-27 (Test Ea, Unpackaged Shock): 50 g Emissions CISPR 11 Group 1, Class A ESD immunity IEC 61000-4-2: 6 kV contact discharges 8 kV air discharges Radiated RF immunity IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 900 Mhz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 Mhz...
  • Page 19 ArmorBlock 2-Port EtherNet/IP Module Certifications Certification (when Value product is marked) c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E322657. European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4;...
  • Page 20 RA-DU002, available at http://www.rockwellautomation.com/literature/. Allen-Bradley, Rockwell Automation, ArmorBlock, and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 1732E-IN004C-EN-E - May 2012 1732E-IN004B-EN-EOctober 2010 Copyright ©...

Table of Contents