Allen-Bradley ControlNet 1786-RPFM Installation Instructions Manual

Modular repeater medium distance fiber module
Hide thumbs Also See for ControlNet 1786-RPFM:

Advertisement

ControlNet Modular Repeater
Medium Distance Fiber Module
Cat. Nos. 1786-RPFM
Use this document as a guide when you install a ControlNet™ repeater fiber module for
medium distances. This document contains:
Topic:
This product is associated with a planning and installation guide, publication
CNET-IN001A-EN-P, The ControlNet Fiber Media Planning and Installation Guide.
To view it, visit www.ab.com/manuals or www.theautomationbookstore.com
Installation Instructions
Page:
10
11
12
12
13
14
15
16
16
17
19
2
3
3
4
4
6
7

Advertisement

Table of Contents
loading

Summary of Contents for Allen-Bradley ControlNet 1786-RPFM

  • Page 1: Table Of Contents

    Installation Instructions ControlNet Modular Repeater Medium Distance Fiber Module Cat. Nos. 1786-RPFM Use this document as a guide when you install a ControlNet™ repeater fiber module for medium distances. This document contains: Topic: Page: Important User Information EMC Directive Low Voltage Directive Fiber Optic Safety Statements Rockwell Automation Support About the Fiber Module...
  • Page 2: Important User Information

    Allen-Bradley publication SGI-1.1, Safety Guidelines for the Application, Installation and Maintenance of Solid-State Control (available from your local Allen-Bradley office), describes some important differences between solid-state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication.
  • Page 3: Emc Directive

    Equipment Requirements and Tests. For specific information required by EN 61131-2, see the appropriate sections in this publication, as well as the Allen-Bradley publication Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. This equipment is classified as open equipment and must be mounted in an enclosure during operation to provide safety protection.
  • Page 4: Fiber Optic Safety Statements

    "Hazardous areas require the use of specifically designed products. This product is designed for Class I, Division 2 hazardous environments, and nonhazardous environments only. Allen-Bradley provides similar products which are ATTENTION intrinsically safe and are suitable for more hazardous environments. Use the appropriate products that are designed for the specific hazardous environments that your installation requires.
  • Page 5 ControlNet Modular Repeater Medium Distance Fiber Module Obtain Pre-Sales Product Support If you need to contact Rockwell Automation for pre-sales product support, try one of the following methods: • Call your local Rockwell Automation representative • Network pre-sales support line, 1.440.646.3638 (3NET) •...
  • Page 6: About The Fiber Module

    ControlNet Modular Repeater Medium Distance Fiber Module About the Fiber Module Use this module when a medium-distance (distances of 3000m/ 9843ft) fiber link is required between two ControlNet products. This fiber link provides ground isolation between nodes and is less susceptible to noisy environments than traditional copper media.
  • Page 7: Mount The Fiber Module

    ControlNet Modular Repeater Medium Distance Fiber Module Mount the Fiber Module To mount the module on the DIN rail: 1. Position the module on a 35 x 7.5mm DIN rail (Allen- Bradley part number 199- DR1; 46277- 3; EN 50022) at a 30 angle.
  • Page 8 ControlNet Modular Repeater Medium Distance Fiber Module 3. Press the module down onto the DIN rail until flush. The locking tab should snap into position and lock the module to the DIN rail. 4. If the module does not snap into position, use a screwdriver or similar device to move the locking tab down while pressing the module flush onto the DIN rail.
  • Page 9 ControlNet Modular Repeater Medium Distance Fiber Module 5. Remove the protective backplane cap as shown in “Remove the Protective Caps” on page 10. 6. Once attached to the DIN rail, slide modules to the left to mate with the repeater adapter or another repeater module. 30043-M Be certain that the adapter and repeater modules are secured ATTENTION...
  • Page 10: Remove The Protective Caps

    ControlNet Modular Repeater Medium Distance Fiber Module Remove the Protective Caps 1. Remove the protective caps from the fiber ports that you are going to use. 2. Save the caps for future use. Figure 2 Protective Caps Protective backplane cap DIN rail Protective cap 42599...
  • Page 11: Choose Fiber Cable Types

    ControlNet Modular Repeater Medium Distance Fiber Module Choose Fiber Cable Types Multi-fiber cables for backbone use are available with a wide range of fiber counts; between 2 and 216 fibers. Rockwell offers the short distance (< 300 m) fiber cable preterminated “zipcord”...
  • Page 12: Specifications For 1786-Rpfm Fiber Optic Cable

    ControlNet Modular Repeater Medium Distance Fiber Module Specifications for 1786-RPFM Fiber Optic Cable The quality of the fiber cable determines the distance you can achieve. Consult your local distributor for attenuation specifications prior to purchasing your fiber media components. The table below provides specifications for fiber optic cable: Item Description Fiber Type...
  • Page 13: Connect The Fiber Cable

    ControlNet Modular Repeater Medium Distance Fiber Module Connect the Fiber Cable If you are going to use only one channel, use either Channel 1 or Channel 2. To connect the cable for Channel 1: 1. Connect to Channel 1 Receive (RX). a.
  • Page 14: Example Topology

    ControlNet Modular Repeater Medium Distance Fiber Module Example Topology Figure 5 This topology is for example purposes only. Create a new segment with a fiber repeater. coax segment coax segment trunk-cable section trunk-cable section fiber segment 41327 When you insert a fiber repeater into your media system, you create a new segment or link.
  • Page 15: Status Indicators

    ControlNet Modular Repeater Medium Distance Fiber Module Be certain that the fiber cable you connect to Channel 1 (RX) IMPORTANT on one 1786-RPFM repeater to Channel 1 (TX) on the other 1786-RPFM repeater. You can use Channel 1 or Channel 2 on either module.
  • Page 16: Related Publications

    ControlNet Modular Repeater Medium Distance Fiber Module Related Publications The table below lists publications that you may want to refer to for additional information: Publication Publication Number Industrial Automation Wiring and Grounding 1770-4.1 Guidelines ControlNet Fiber Media Planning and CNET-IN001A-EN-P Installation Manual ControlNet Coax Tap Installation Instructions 1786-5.7...
  • Page 17: Specifications

    ControlNet Modular Repeater Medium Distance Fiber Module Specifications Specification Range Communication Rate 5M bits/s Operation Voltage Class 2 operational power is provided from 1786-RPA at 5 V dc Backplane Power Requirements 400 mA maximum Indicators Channel 1 Status - Green Channel 2 Status - Green Environmental Conditions This product must be mounted within a suitable system enclosure...
  • Page 18 ControlNet Modular Repeater Medium Distance Fiber Module Specification Range Fiber Type 62.5/125 micron ® Fiber TerminationTypeST (plastic or ceramic) Fiber Operating Wavelength 1300 nm Optical Power Budget 13.3 dB LED Light Output <5 mW/mm Agency Certification (when product or package marked) Listed Industrial Control Equipment Certified Process Control Equipment Certified Class 1, Division 2, Groups A, B, C, D...
  • Page 19: Hazardous Location Approval

    ControlNet Modular Repeater Medium Distance Fiber Module Hazardous Location Approval The following information applies when operating this equipment in hazardous locations: Products marked “CL I, DIV 2, GP A, B, C, D” are suitable for use in Class I Division 2 Groups A, B, C, D, Hazardous Locations and nonhazardous locations only.
  • Page 20: Publication 1786-In011B-En-P - October

    Notes: Publication 1786-IN011B-EN-P - October 2000 PN 957400-85 Supersedes 1786-5.11 - February 1998 © 2000 Rockwell International Corporation. Printed in the U.S.A.

Table of Contents