5-3. Switch Transmission Mode

Z108A performs two transmission modes: the data-transmission mode (default) and the
command-transmission mode.
To switch the modes, please use this command format:
02
The command to switch to data-transmission mode
"020FFE117777772E6E6574766F782E636F6D2E636ECB"
It is actually "www.netvox.com.cn"
After it switches to data-transmission mode successfully, the stream "021FFE0100E0" is returned.
In data transmission, Z108A broadcasts data wirelessly. Raw data '010203', for example, can be entered and
transmitted directly. Raw data can also be received wirelessly without any need of conversion. The data
received can be ported to serial connection of, for example, a PC.
The command to switch to command-transmission mode
"020FFE115757572E4E4554564F582E434F4D2E434ECB"
It is actually "WWW.NETVOX.COM.CN"
After it switches command-transmission mode successfully, the stream "021FFE0100E0" is returned.
The module strictly follows Profile Command to sent and receive control commands.

5-4. Control and Management

Users could use ZiG-BUTLER to manage your ZigBee network. From ZiG-BUTLER, you are able to send
commands (such as On/Off) to the ZigBee network. Follow the instructions bellow for control and
management.
Step1. Run ZiG-BUTLER. Go to System → Select ZigBee Adapter/Gateway
Cmd=0x0FFE