INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE AND SERVICING. THIS APPLIANCE WILL BECOME VERY HOT WHEN USED IN ACCORDANCE WITH THESE INSTRUCTIONS, HUNTER STOVES RECOMMEND THAT AN APPROVED GUARD IS USED TO PROTECT THE YOUNG, ELDERLY OR INFIRM FROM HARM.
ARBON ONOXIDE ETECTOR remove. Hunter Stoves recommend a Carbon Monoxide Detector that conforms to the latest issue of BS EN 50292 is placed in the same room as the appliance. The installation of such an alarm is not considered as...
Rear Brick APPLIANCE DIMENSIONS KESTREL Pull the top edge of the Rear Brick forward and lift the brick out of the Stove. Baffle/Throat Plate Lift the Baffle and slide to the right. When the left side of the Baffle clears the Baffle Support, lower the Baffle into the Fire Box and remove...
flue pipe must not exceed 125mm or 152mm (as above). It is essential that all connections between the stove and chimney-flue are sealed and made airtight. Make provision to access the chimney/flue system for cleaning and the removal of debris. If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations Approved Document J, or a twin-walled insulated...
(Kestrel, EGAL EQUIREMENTS Hawk 3 & 4, Herald 4/5C/5S/8S. These stoves listed Hunter Stoves Group requests that before installation below require a permanent, unobstructed air and/or use of this appliance that you read these opening: instructions carefully to ensure that all the relevant Herald 6 –...
Ensure the Air Controls are working correctly. mm thick (this may include the thickness of a solid Hunter Stoves Group recommend that you carry out a floor and a non-combustible decorative hearth). smoke draw test to check the soundness of the...
Page 14
Fuel overloading Hunter Stoves Group also recommend that a CO alarm The maximum amount of fuel specified in this manual is fitted into the room where the appliance is located. should not be exceeded, overloading can cause excess...
Operation with door left open It is essential that the stove has an adequate air Operation with the door open can cause excess smoke. The supply for combustion and ventilation. appliance must not be operated with the appliance door The primary and secondary air inlets must be kept left open except as directed in the instructions.
Page 16
fuel bed from front to back. It should not be stacked Once you have a good fire established across the above the level of the rear firebrick as this grate bed, further fuel can be added as required and may result in damage to the stove. With a full load of the air controls set to the correct position.
This should be removed and cleaned at least once a Recommended Fuels month to prevent any build-up of soot or fly ash that Hunter Stoves Group recommend that only wood logs could lead to blocked flue ways and dangerous fume with a moisture content of less than 20% and emission.
Page 18
The appliance may emit unpleasant odours during this ordered from the Hunter Stoves Group spares range. process, please ensure the room is well ventilated. HIMNEY AND...
TROUBLESHOOTING ISSUE CAUSE RESOLUTION Problem starting the fire and Low flue draught Speak to your installer keeping it burning Wood with moisture content over 20% Ensure use of dry seasoned wood with less than 20% moisture content Unable to control fire High flue draught Speak to your installer Short burn time...
Page 20
ISSUE CAUSE RESOLUTION Creosote build-up in chimney Wood with moisture content over 20% Use dry seasoned wood (less than 20% moisture content). Operate at a high temperature for short periods each time the appliance is used to avoid large build-ups of tars and creosotes.
Page 33
HIGH OUTPUT INGLENOOK – MULTIFUEL HIGH OUTPUT INGLENOOK – WOOD TOP AIR DEFLECTOR (MULTIFUEL & WOOD) LOW OUTPUT HIGH OUTPUT Slider HHR14069 HHR08027 Slider Plate HHR14070 HHR14070 Gasket HHR14071 HHR14071 Shaft HHR14073 HHR14073 Knob HHR08045 HHR08045 Deflector Single Door – HHR14074 Single Door – HIN16015 Double Door –...
INSTALLATION & COMMISSIONING CHECKLIST PURCHASE INFORMATION Dealer/Retailer Name Address Telephone Number Email Date Purchased INSTALLER INFORMATION Installer Name Address Telephone Number Email APPLIANCE INFORMATION Date Installed Appliance Stock Code Appliance Description Serial Number COMMISSIONING CHECK (Complete & Sign) Does the chimney/flue system meet the appropriate standard? Has the chimney/flue system been swept and passed the soundness test? Has this appliance passed the flue draught test? Please write down the flue draught reading:...
SERVICE RECORDS Service Service Date of Service Date of Service Date of next Service Date of next Service Servicing Company/ Servicing Company/ Engineer Engineer Signature Signature Service Service Date of Service Date of Service Date of next Service Date of next Service Servicing Company/ Servicing Company/ Engineer...
This is needed in the event of a claim during the warranty period. Only genuine Hunter Stoves spare parts or consumables can be used in the servicing and maintenance of the appliance during any standard or extended warranty period. These can be sourced from your authorised supplier directly or through our website spares portal.
Page 39
Cost associated with the removal and re-installation of an appliance subject to a warranty claim. Hunter Stoves Group total liability will only extend to the total purchase price paid for the goods in any warranty claim. Hunter Stoves Group reserve the right to replace, repair or refund to value of goods purchased.
Page 40
Further Information For extra guidance on using your stove, please visit our YouTube channel by searching ‘Hunter Stoves Group’ or see the helpful hints section of our website; www.hunterstoves.co.uk. This appliance is suitable for intermittent burning. This appliance should not be used in a shared flue.