The following section describes the activities generally needed to maintain and clean the OVH-10/11-FB Hood.
Attention to these procedures will help ensure that the Hood remains in good condition and continues to run
efficiently and safely.
A Maintenance & Service Log is provided in this manual to help track these activities, see Table 5.03.

5-01. Monthly Interlock Check

The Hood features various interlock devices to ensure that the unit is shutdown in the event that conditions arise that
are not consistent with safe and effective operation. These interlocks should be tested MONTHLY as described below.
Use the Maintenance & Service Log and check the box that corresponds to each functional test. If a problem is
found, contact an authorized service provider.
1.
Door Interlock Check: Turn power switch ON. With Hood running, remove the Filter Access Door, as
described in Section 4-02.2. Confirm that the Hood does shutdown when door is removed, and that the
under-hood appliance cannot be operated.
2.
Baffle Filter Check: Place power switch in the OFF position; remove the Baffle Filter, see Section, 4-02.2.
Replace Access Door and turn ON power. The red Baffle or Charcoal Filter Missing light should illuminate
and the Appliance Powered light should be OFF. Confirm that the under-hood appliance cannot operated.
Turn power OFF and reinstall the Baffle Filter.
3.
EAC Filter Check: Place power switch in the OFF position; remove the EAC Filter Cell, see Section 4-02.2.
Replace Access Door and turn ON power. All three EAC status lights should illuminate and after
approximately 2 minutes, an intermittent tone (beeping) alarm should sound. The Appliance Powered light
should turn OFF. Confirm that the under-hood appliance cannot operated. Turn power switch OFF and
reinstall EAC Filter Cell.
4.
Charcoal Filter Check: Place power switch in the OFF position; remove the Charcoal Filter, see Section 4-
02.2. Replace Access Door and turn ON power. The red Baffle or Charcoal Filter Missing light should
illuminate and the Appliance Powered light should be OFF. Confirm that the under-hood appliance cannot
operated. Turn power OFF and reinstall the Charcoal Filter.
5.
Filter Clogged Check: Perform this check ONLY after installing a new Charcoal Filter. The easiest method
for checking the clogged filter interlock is to completely block the Hood exhaust outlet with piece of
cardboard while the hood is running and the appliance power is ON. A continuous tone alarm should sound
when the exhaust is blocked, the red Baffle or Charcoal Filter Clogged light should illuminate and the
Appliance Powered light should turn OFF. The appliance should also turn OFF during this time. Remove the
obstruction; the alarm should silence and power should be restored to the appliance. If the alarm tone does
not sound, fails to silence, or the appliance fails to turn OFF or turn ON, contact a service agent to have the