2.4 ELECTRIC WIRING
For the connection of the bollard to the control unit, use a multi-pole cable, type FG7OR-0,6/ kV- 16G 1.5 (16 cables of 1.5mm2) with max. length
of 50 m. This cable must be laid inside a sheath ø 45mm, secured to the cable clamp in the bottom part of the frame (fig. 8 ref.
come out of the pit by 2.5 m.
Perform the electric wiring in the junction box on the bollard side, as shown in Fig. 13.
Any additional accessory (i.e. photocells, opening/closing push-buttons, etc.), that have to be connected to the control unit, must compulsorily have
double insulation.
³
J355HA M30-P1
³
³
10
) and must
8
732768 - Rev.C