Electrical Wiring - FAAC J355HA M50 Translation Of The Original Instructions

Hide thumbs Also See for J355HA M50:
Table of Contents

Advertisement

2.4 ELECTRICAL WIRING

To connect the bollard, use a multi-pole cable such as FG7OR-0.6/1kV-
16G1.5 (16 wires of 1.5mm2) between bollard and control board and a
FG7OR-0.6/1kV-3G4 cable (3 wires of 4 mm2) for the motor power supply,
both measuring a maximum of 50 metres in length.
The cables must be laid inside a sheath of Ø50mm and passed through
the cable guides provided on the pit sheet (8-1) and through the
two corrugated conduits supplied with the pit.
Pass the wires through on the guides on the bollard frame as per as
8-2 then connect the corrugated conduits to the supports on the
bollard frame, as indicated in 8-3.
Complete the electrical connections in the terminal box at the side
of the bollard as shown in 14.
3
2
J355HA M50
Any additional accessories (e.g. Open/close buttons, etc.) that are
connected to the control board must be double insulated.