Toyotomi FR-700F Installation And Operation Instructions Manual page 8

Vented heating system
Table of Contents

Advertisement

4. Igniting the heater
The heater is operated directly by the user. You can
choose the heat yield is controlled automatically in
accordance with the room temperature registered by the
temperature sensor or selected manually by setting the
heat adjusting slide knob.
Step 1: Switch the heater ON
Press the ON/OFF button. The current room temperature
is displayed on the information display when the heater
is in the manual operation. However the set temperature
is also displayed when you choose the automatic
operation. The ON/OFF light starts to flash, after which
the heater will switch on.
Note: (*) The start-up time depends on the
room temperature.
After 8-12 minutes, the heater will automatically select
the correct operating mode and the ON/OFF button will
now be illuminated continuously.
Room temperature:
under 0˚C
12 minutes
0˚C - 15˚C
10 minutes
15˚C
8 minutes
If no flames are visible after the start-up period, the
heater will deactivate and then restart automatically. If
flames are still not detected, the heater will deactivate
and will have to be restarted manually (error code E-2
on the information display).
Step 2: Setting the room temperature
Set the heat adjusting slide knob to left-side "Auto"
position. The temperature setting can only be adjusted,
when the heater is burning.
buttons to adjust the temperature. First press either of
the two buttons to switch on the function (the TEMP
light next to the information display will start blinking).
Next, adjust the temperature using the button on the
right (+MIN.) to set the temperature to a higher setting
and the button on the left (-HOUR) to lower the
temperature.
Press once to increase the value one
step. After approximately 10 seconds the light will stop
blinking and setting will belocked. The available
temperature settings range from10˚C minimum to 32˚C
maximum. When the heater has been unplugged (or
after a power failure), the temperature will reset to the
factory setting of 20˚C.The operating mode is
automatically controlled in accordance with the room
temperature detected by the room temperature sensor.
The heater works in the "HIGH" operating mode until
the room temperature has reached the desired level.
7
When the room temperature reaches the chosen
setting the heater automatically switches to the "MED"
or "LOW" operating mode in order to maintain the
desired temperature.
Step 3: The correct use of 'SAVE'
The 'SAVE' function allows you to limit the temperature.
When this function is activated, the heater will
automatically switch off, when the room temperature
exceeds theset temperature by 2˚C. Subsequently, when
the roomtemperature has dropped again to the set
temperature,the heater will automatically switch on
again. Activatethe 'SAVE' setting by pressing the
appropriate button.The SAVE indicator light will light up.
Switch off thefunction by pressing the SAVE button once
again.
Step 4: Setting the heat yield (Manual operation)
Adjust your desired combustion mode by setting the
heat adjusting slide knob between "LOW" and "HIGH".
The combustion will keep the selected position.
Use the adjustment
Without the 'SAVE' setting your heater will
maintain the set temperature by approxima-
tion as well, by adjusting its heating capacity.
'SAVE' is an economy setting, which you can
use when, for in stance, you are not present
in the room or to keep it frost-free.
The first 8-12 minutes from switched ON the
heater, the heater will keep "Min." combus-
tion mode for the pre-combustion.
After that, the combustion will change
automatically to selected position.
You cannot change the heat yield first 8-12
minutes.

Advertisement

Table of Contents
loading