Toyotomi FR-700F Installation And Operation Instructions Manual page 20

Vented heating system
Table of Contents

Advertisement

4.
Insert the bent joint to the exhaust opening of the flue pipe. Cut the inlet hose for desired length if necessary.
Attach the L-shaped hose to each end of the inlet hose and attach the L-shaped hose to the intake opening of the
flue pipe. Secure the L-shaped hose to the intake opening with the hose band. Plug the unused exhaust and
intake opening with the caps provided with the heater. Make sure the caps fit tightly onto the opening (See Fig. 6).
Inlet Hose
L-Shaped Hose
NOTE: If the inlet hose is not smoothly inserted into the L-shaped hose, apply water or soap suds to the inlet
hose.
5. Move the heater into position. Connect the bent joint to the exhaust outlet opening (upper opening) and attach
the L-shaped hose to the intake inlet opening. Make sure all connections are tight (See Fig. 7).
19
Hose Band
Exhaust
Air Cap
Fig. 6
Outlet Opening
Inlet Opening
Fig. 7
Intake Air Cap
Exhaust Opening
Bent Joint
Bent Joint
L-Shaped Hose