2) RETAIN INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE. 3) CHECK LOCAL AUTHORITY & BUILDING CODES FOR INSTALLATION REQUIREMENTS. SECTION A: SPECIFICATIONS Model: FF-55T/FF-55 Heater Efficiency: 92.4% (1) Heat Rating: High - 5.50 kW (18,800 BTU/h) Med - 3.74 kW (12,800 BTU/h) Low - 1.88 kW ( 6,430 BTU/h)
SECTION C: FUEL GUIDE The FF-55T/FF-55 is designed for use with Paraffin. Use of low-quality fuel will cause burner performance to drop, leading to abnormal combustion and reduced heater life. Purchase only Paraffin, in non-red cans reserved exclusively for fuel and marked accordingly with the word “PAR- AFFIN”.
OPERATING CONTROLS AND PART NAMES Before using heater, familiarize yourself with the following operating controls and part names. Ciraulation air filter 17. Circulation fan Control panel Removable fuel tank FF-55T Front panel 18. Room temperature sensor Combustion flames peep hole...
OPERATION BEFORE IGNITION 1. Filling Fuel FF-55T: • Do not fill the removable tank in the living room, but in a more suitable place(there can always be some spillage). • Do not refuel the heater while in operation or still hot.
Page 7
As the room temperature becomes lower than the selected setting, the heater will automatically re-start to maintain the desired temperature. FUEL INDICATOR LIGHT (FF-55T) When the information display lights up, fu 10 , it means that there is only fuel left for 10 more minutes. The count down of the remaining heating time can be seen in the information display.
Page 8
ENGLISH CHILD LOCK OPERATION The childproof lock can be used to prevent children accidentally changing the heater settings. When the heater is burning and the childproof lock is on, the heater can only be switched off. Other functions are blocked then. If the heater has already been switched off, the childproof lock also prevents accidental ignition of the heater.
Page 9
ENGLISH 4) Set the temperature of the program The set temperature “21” will be shown on the display and it will flash. 1. Press the “sMIN.” button or the “tHOUR” button to set the temperature of the program. 2. Press the “SET” button to complete the set the temperature of the program and move to the next step (5) Set a day of the week of the program).
ENGLISH MANUAL COMBUSTION IMPORTANT: This feature is for testing purpose only! This heater also can be kept burning at desired combustion mode (High, Medium or low) manually, regardless of room temperature. 1. Press the “sMIN.” button and “tHOUR” button at the same time for more than three (3) seconds when ON / OFF switch is “ON”.
Once a week slide the filter up to remove and it should be vacuumed clean. 3. Clean Fuel Acceptance Fitting (FF-55T) When dirt or dust accumulates in the fuel acceptance fi tting, it should be cleaned. Check fuel acceptance fi tting each time your refuel.
Page 12
ENGLISH 4. Check for Fuel Leaks (REGULARLY) FF-55T: Make it a habit to check for signs of fuel leakage. Wipe off any spilled fuel on the sub tank and removable fuel tank. Spilled fuel may cause odor or risk of fire.
Ignition failure three times Contact your dealer. E-23 Primary flame rod (Flame sensor) is malfunction and/or dirty Consult your dealer. FUEL No fuel (FF-55T) Refill fuel. (FF-55T) -- : -- Timer is not setting. Set the timer. Room temperature is higher than 35˚C (95˚F).
Take the following measures to avoid fuel leakage during the transportation of the heater. - ALWAYS move the heater in an upright position. - ALWAYS drain fuel from the fuel sub tank cap (*optional) (Part #17217535) before transportation. (FF-55T) - ALWAYS drain fuel from the fuel sump before transportation. (FF-55)
SECTION I: INSTALLATION GENERAL DESCRIPTION: The FF-55T/FF-55 is designed to be installed in an outside wall so the full advantage of installation simplicity can be made with the “Flue Pipe”, which eliminates the need for tall chimney type flues. No hearth or fire surround is required.
ENGLISH INSTALLATION ADVICE 1. Intake air and exhaust flue pipe openings of the Flue Pipe must be fully exposed to outside. The Flue Pipe must not vent into a chimney, garage, basement, under-floor or ceiling cavity, or any enclosed area, or be installed vertically, because the Flue Pipe is a “Heat Exchanger”...
C) The FF-55T / FF-55 heater is designed to be operated at altitudes up to 900 m, above sea level. For installation at altitudes between 900 m and 1500 m, adjustments by authorized serviceperson is necessary. Consult your supplier for advice.