Hub status includes a matrix of information about the hub ports. In this
matrix, Y indicates yes and n indicates no. (See Table A-3.)
Table A-3 Hub Status Information
Category
Port is enabled
Link state is up
Auto-negotiate link
configuration
Advertise outgoing
flow control
Advertise incoming
flow control
Enable outgoing flow control
Enable incoming flow control
State Description
Y
The port is enabled for linking.
n
The port is disabled for linking.
Y
A link exists between the port and a device.
n
No link exists between the port and
a device.
Y
The port is set for auto-negotiation.
n
The port is set for forced link.
Y
The port signals outgoing flow
control capability.
n
The port does not signal outgoing flow
control capability.
Y
The port signals incoming flow
control capability.
n
The port does not signal incoming flow
control capability.
The port does not support incoming
flow control.
Y or n If auto-negotiation is enabled, the result of
the negotiation between the port and the
linked device is shown. If auto-negotiation
is disabled, the flow control you specify
is shown.
Y or n If auto-negotiation is enabled, the result of
the negotiation between the port and the
linked device is shown. If auto-negotiation
is disabled, the flow control you specify
is shown.