Logging Off; Troubleshooting - 3Com Hub 1000 SX User Manual

3com hub user guide
Table of Contents

Advertisement

Logging Off

Troubleshooting

7 When prompted, enter the filename of the firmware image file.
The terminal-emulation program begins to transfer the firmware image
file. If you want to stop the file transfer, use the appropriate command in
the terminal-emulation program.
After the transfer is finished, the CLI displays the following message:
File transfer successful.
Firmware update successful.
If the runtime software is corrupted (for example, if power is interrupted
during a firmware update), the CLI displays the following message:
Runtime image not valid.
The CLI prompts you to restart the file transfer, without requiring you to
log in again. To restart the file transfer, repeat steps 6 and 7.
To log off the CLI, at the Hub 1000 SX Configuration menu
prompt, enter:
5
***************************************************
**
Hub 1000 Configuration Menu
***************************************************
[1]
Configure port settings
[2]
Display hub status
[3]
Update firmware image
[4]
Change password
[5]
Logout
Enter choice -> 5
The screen returns to the CLI header and the password prompt.
If a firmware update error occurs, the UNIT STATUS LED flashes
amber/green. Press the Reset button on the Hub 1000 SX rear panel and
repeat the procedure for updating the firmware. If the UNIT STATUS LED
continues to flash amber/green, return the unit to the supplier.
Table A-4 summarizes error messages that may appear during a file
transfer and actions you can take to correct the errors.
Logging Off
A-17
**