Mitsubishi MELSEC L Series User Manual page 257

Communication module
Hide thumbs Also See for MELSEC L Series:
Table of Contents

Advertisement

11 - 19
(3) Examples of registering a receive user frame
The following are examples of pre-registering a receive user frame on the CH1
side with the GX Configurator-SC.
(a) When the first frame is specified
In the example, the following three combinations are registered for the
receive user frame.
[Setting conditions]
User frame
1st
(First frame + last frame)
combination
2nd
(First frame only)
combination
3rd
(First frame only)
combination
[Setting value]
Setting item
Received data count designation
Receive complete code designation
User frame use enable/disable
designation
Receive user frame designation
First frame No. designation
Receive user frame designation
Last frame No. designation
User frame receive format
designation
Exclusive format-1 received data
count designation
11 DATA COMMUNICATIONS USING USER FRAMES
User frame receive
format designation
Format-0
Format-1
Format-1
Setting value
1FF
H
FFFF
H
Enable
1st
3E8
H
2nd
3E9
H
3rd
3EA
H
4th
0
H
1st
41D
H
2nd
0
H
3rd
0
H
4th
0
H
1st
Format-0
2nd
Format-1
3rd
Format-1
4th
Format-0
1st
0
H
2nd
0
H
3rd
2
H
4th
0
H
Exclusive format-1
received data count
The received data
count becomes valid.
0
Exclusive format-1
H
received data count
becomes valid.
2
H
Remarks
For Format-0
Set to "No receive complete code".
Always specify "Enable".
0
: No designation
H
1
or higher: There is a designation.
H
In this setting, only three combinations
become valid.
The received data count becomes valid.
Exclusive format-1 received data count
becomes valid.
For Format-1
Remarks
11 - 19