Market Forge Industries ALTAIR II Series Installation, Operation And Maintanance page 13

Convection steamer
Table of Contents

Advertisement

Monthly Cleaning
Market Forge recommends using Optipure DSP descal-
ing powder to clean your steamer on a monthly basis or
whenever necessary.
NOTE: Optipure DSP is an acid based descaler that is
effective in dissolving and removing build up
caused by hard water. DSP is a non-hazardous,
biodegradable citrus based powder that when
mixed with water becomes a powerful lime scale
remover. For additional information contact Opti-
pure at 800-535-5035.
1. Make sure the steamer is off and cool.
2. Drain water from the cooking cavity and wipe away
any food debris.
3. Make sure the drain is plugged.
4. Pour one pound of Optipure DSP per steamer into the
bottom of the cooking cavity.
NOTE: One pound is equal to 16 scoops (measuring
scoop included), or one-half of a 2lb. jar of
descaling powder.
5. Set the control to Steam (#2) position. This will auto-
matically fill the unit with water.
6. Allow the unit to reach steaming temperature and
continue steaming for one hour.
7. Turn the unit off, and allow it to cool for one hour.
8. Drain the unit, and rinse the entire cooking chamber
thoroughly.
9. If the unit is heavily scaled, it may be necessary to
repeat the process.
Cleaning Guidelines