Altair Ii-8, Altair Ii-10 And Altair Ii-12 - Market Forge Industries ALTAIR II Series Installation, Operation And Maintanance

Convection steamer
Table of Contents

Advertisement

Service Connections
ELECTRICAL CHARACTERISTICS
ELECTRICAL (4 PAN STEAMER) 60 Hz
Voltage
pH
208
1
240
1
208
3
240
3
480
3
ELECTRICAL (6 PAN STEAMER) 60 Hz
Voltage
pH
208
1
240
1
208
3
240
3
480
3
24.00 [610]
3.88
19.00 [483]
[98]
4.75
[121]
2.00
[51]
20.00 [508]
FRONT VIEW
INSTALLATION

ALTAIR II-8, ALTAIR II-10 AND ALTAIR II-12

kW
Amps
8
38.5
8
33.3
8
22.2
8
19.3
8
9.6
kW
Amps
9.8
47.1
9.8
40.8
9.8
27.2
9.8
23.6
9.8
11.8
DIMESIONS ARE IN INCHES [MM]
Altair II-8
A
Altair II-10
B
C
Altair II-12
6.00 [152]
WATER SUPPLY & DRAIN
Good quality water feed is the responsibility of the owner. Water quality must be within the
following general guidelines.
TDS: 40-125 ppm
Hardness: 35-100 ppm
Silica: <13 ppm
Chlorides: <25 ppm
Chloramine: <0.2 ppm
The best defense against poor water quality is a water treatment system designed to meet
your water quality conditions.
Pressure:
25(min)-50(max) PSI
Connections: Trough drain: 1/2 MNTP Drain out: 1" FNPT Water: 3/4" male garden hose
Appliance to be installed with backflow protection according to federal, state or local codes.
The drain piping must consist of temperature resistant material, greater than 160°F, and be
of adequate diameter not to cause flow restriction. Improper materials may deform and cause
restrictions, thus affecting performance.
NOTES
„ Each single compartment has a separate rear exiting drain plumbed directly into the
stacked steamers main drain/vent line.
„ 4" clearance left mandatory, right and rear is recommended.
„ Location near a floor drain is recommended.
„ Refer to electrical characteristics chart for voltage requirements of each steamer.
„ Each compartment requires separate electrical & water connection.
30.75 [781]
28.75 [730]
2.00
[51]
2.00 [51]
22.00 [559]
SIDE VIEW
Figure 2
4
pH: 7.0 - 8.5
Chlorine: <0.2 ppm
Steam Vents
17.75
[451]
Pull out
service
drawer
Door is in
open position
Water in each unit
4.75 [121]
requires water line
REAR VIEW
2.00
[51]
3.25 [83]
8.50 [216]