Dil Switch Selector; Host Settings - Bosch AMC2 Installation Manual

Modular controller
Hide thumbs Also See for AMC2:
Table of Contents

Advertisement

26
en | Installing
4.11

DIL switch selector

4.11.1

Host settings

DIL switches are used to configure the host settings. The first four DIL switches for address
selection define the RS-485 address of the AMC2 in a RS-485 bus system. Switch 5 selects
one of the two different protocols, SDEB and BPA (according to DIN6619).
Switch 6 sets the connection to the host system to either RS-232 or RS-485.
Notice!
If using an Ethernet connection, set switch 1 to ON (= factory setting).
If using an RS-232 connection, set the address by configuring it in the Access Control System.
This is a point-to-point connection that is usually configured as address 1, so set switch 1 to
ON.
Figure 4.15: Location of the selector for host settings
Address
None
1
2
3
4
5
6
7
8
Tab. 4.1: Setting the address via the DIL switch
Instructions for DIL switch 5
Set SDEB (= DIL switch 5 to ON) in the following cases
Set BPA (= DIL switch 5 to OFF) in the case of an
2018-02 | AMC2-4R4 |
DIL Switches
1
2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
Ethernet host connection
RS-485 host connection, provided only one AMC2 is connected on the bus
3
4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
Installation Manual
AMC2 Modular Controller
Bosch Access Systems GmbH

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amc2-4r4

Table of Contents