6.1

Connections and control devices

1
Control panel,
(see separate instruction manual)
2a
Connection for remote control unit
2b
Connection for U8
3
Connection BLUE, with ELP* for coolant to
the welding gun
4
Connection RED, for coolant from welding
gun
5
Connection for welding gun
Note! Coolant connections only available on certain models.
* ELP = ESAB Logic Pump, see point 6.2.
bm44d1ea
2
6
Connection for welding current from power
source, (OKC)
7
Connection for control cable from power
source or cooling unit
8
Connection RED, for coolant to cooling
unit
9
Connection for shielding gas
10
Connection BLUE, for coolant from cooling
unit