TECHNICAL DATA

Power supply
Power requirement
Motor current I
max
Wire feed speed
Gun connection
Max. diameter wire bobbin
Wire dimension
Fe
Ss
Al
Cored wire
Weight
Dimensions (l x w x h)
Operating temperature
Shielding gas
max pressure
Type of cooling
max pressure
Maximum permissible load at
60% duty cycle
Enclosure class
with sealed bobbin holder
without sealed bobbin holder
* Accessories, see page 18.
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or cut at
a certain load without overloading. The duty cycle is valid for 40° C.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP23 is designed for indoor and outdoor use.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Apparatus marked IP2X are intended for indoor use.
5

INSTALLATION

The installation must be executed by a professional.
bm44d1ea
Feed L3004
42 V 50-60 Hz
180 VA
3.5 A
0.8 - 25.0 m/min
EURO
300 mm (*440 mm)
0.6 - 1.2 mm
0.6 - 1.2 mm
1.0 - 1.2 mm
0.8 - 1.2 mm
15 kg
690 x 275 x 420 mm
-10 to +40° C
All types intended for MIG/MAG welding
0.5 MPa (5 bar)
50% water / 50% mono-ethylen glycol
0.5 MPa (5 bar)
365 A
IP23
IP2X
- 6 -