Displaying Measurement Results

Limit Testing

Limit Testing
The measurement trace can be automatically compared to limits which
you define. The limits, entered as lines and points, can be displayed on
the screen or can be hidden. Whether or not the limits are displayed, the
analyzer will display "PASS" if the measurement satisfies the limits and
will display the FAIL
prescribed limits. Using limits gives the operator visual guides when
tuning devices, provides standard criteria for meeting device
specifications, and shows an instant indication of the comparison of data
versus specifications.

To turn limit lines on or off

To turn limit lines on or off, press
Limit Options Limit Line ON off
commands:
CALC[1|2]:LIMit:DISPlay ON
CALC[1|2]:LIMit:DISPlay OFF
where [1|2] indicates the measurement channel number; use either
1 or 2.

To turn the fail icon on or off

To turn the fail icon on or off, press
Limit Options Limit Icon ON off
commands:
DISP:ANN:LIM:ICON[1|2]:FLAG ON
DISP:ANN:LIM:ICON[1|2]:FLAG OFF

To turn the pass/fail text on or off

To turn the pass/fail text on or off, press
Limit Options Limit Text ON off
commands:
DISP:ANN:LIM:ICON[1|2]:TEXT ON
DISP:ANN:LIM:ICON[1|2]:TEXT OFF
7-4
symbol if the measurement fails to meet the
DISPLAY
, or use the following SCPI
DISPLAY
, or use the following SCPI
DISPLAY
, or use the following SCPI
Automating Measurements
Limit Menu
Limit Menu