Vitotrol 200-Rf - Viessmann VITODENS 200-W Type B2HA Technical Manual

Wall mounted gas condensing boiler
Hide thumbs Also See for VITODENS 200-W Type B2HA:
Table of Contents

Advertisement

Control units
(cont.)

Vitotrol 200-RF

Part no. Z011219
Wireless subscriber
■ Displays:
– Room temperature
– Outside temperature
– Operating condition
– Wireless signal reception quality
■ Settings:
– Set room temperature for standard mode (normal room tempera-
ture)
Note
The set room temperature for reduced mode (reduced room
temperature) is set at the control unit.
– Operating program
■ Party and economy mode can be enabled via keys
■ Integral room temperature sensor for room temperature hook-up
(only for one heating circuit with mixer)
Installation location:
■ Weather-compensated mode:
Installation anywhere in the building
■ Room temperature hook-up:
The integral room temperature sensor captures the room tempera-
ture and effects any necessary correction of the flow temperature.
The captured room temperature depends on the installation site:
– Main living room on an internal wall opposite radiators
– Not on shelves or in recesses
– Never in the immediate vicinity of doors or close to heat sources
(e.g. direct insolation, fireplace, TV set, etc.)
Note
Observe the "Wireless accessories" technical guide.
5
Wireless base station
Part no. Z011413
KM-BUS subscribers
For communication between the Vitotronic control unit and
Vitotrol 200-RF wireless remote control.
For up to 3 wireless remote control units. Not in conjunction with a
hardwired remote control unit.
Connection:
■ 2-core lead, length up to 50 m (even when connecting several KM-
BUS subscribers).
■ Never route this cable immediately next to 230/400 V cables.
VIESMANN
88
3 4
1 4
8
Specification
Power supply
2 AA batteries 3 V
Radio frequency
868 MHz
Wireless range
See "Wireless accessories" technical
guide
Protection class
III
IP rating
IP 30 to EN 60529; ensure through de-
sign/installation
Permissible ambient temperature
– Operation
0 to +40 °C
– Storage and transport
−20 to +65°C
Setting range of the set
room temperature for
standard mode
3 to 37 °C
Specification
Power supply via KM-BUS
Power consumption
1 W
Radio frequency
868 MHz
Protection class
III
IP rating
IP 20 to EN 60529; ensure through de-
sign/installation
Permissible ambient temperature
– Operation
0 to +40 °C
– Storage and transport
−20 to +65 °C
VITODENS 200-W