Installation accessories
2
5 9
9
a Adjustable to appliance width
Immersion temperature sensor (for low loss header)
Part no. 7179488
To capture the low loss header temperature.
CO limiter
Part no. Z015500
Monitoring device for safety shutdown of the boiler in the event of
escaping carbon monoxide.
Wall mounting in the ceiling area near the boiler.
Components:
■ Casing with
– Integral CO sensor
– Mode, fault and alarm indicators
– Acoustic alarm system
■ Communication cable for interface (2.5 m).
■ Interface inside the casing with power cable (1.2 m) and connect-
ing lead for burner shutdown relay (1.2 m)
■ Fixing materials
5 8
VIESMANN
32
(cont.)
a
0
7 2
1 3
Additional sensor for dual sensor well. For dual mode or multi
mode heating systems.
Specification
Rated voltage
230 V~
Rated frequency
50 Hz
Power consumption
2 W
Rated breaking capacity
8 A 230 V~
of the relay output
Alarm threshold
55 ppm CO to EN 50291-1
Protection class
II
IP rating
IP 20 to EN 60529; ensure through de-
sign/installation.
Permissible ambient tem-
0 °C to 40 °C
perature
VITODENS 200-W