Vitotrol 300A; Information Regarding The Vitotrol 200 Rf And Vitotrol 300 Rf; Vitotrol 200 Rf - Viessmann VITODENS 200-W Technical Manual

Gas condensing boilers 17.0 to 150.0 kw as multi boiler system up to 900.0 kw
Table of Contents

Advertisement

Control units
(cont.)

Vitotrol 300A

Part no. Z008 342
KM BUS subscriber
■ Indications:
– Room temperature
– Outside temperature
– Operating program
– Operating condition
– Solar yield as graphic display
■ Settings:
– Set room temperature for standard mode (day temperature) and
reduced mode (night temperature)
– Set DHW temperature
– Operating program, switching times for heating circuits, DHW
heating and DHW circulation pump plus further settings via plain
text menu on the display
■ Party and economy mode can be enabled via the menu
■ Integral room temperature sensor for room temperature hook-up
(only for one heating circuit with mixer)
Installation site:
■ Weather-compensated mode:
Installation anywhere in the building.
■ Room temperature hook-up:
The integral room temperature sensor captures the actual room
temperature and corrects the flow temperature if necessary.
The captured room temperature is dependent on the installation site:
– Main living room on an internal wall opposite radiators.
– Not on shelves or in recesses.
– Never install immediately by a door or heat source (e.g. direct
sunlight, fireplace, TV set, etc.).
Connection:
■ Two-core cable, length max. 50 m (even if connecting several
remote control units).
■ Never route this cable immediately next to 230/400 V cables.
■ LV plug as standard delivery.

Information regarding the Vitotrol 200 RF and Vitotrol 300 RF

Wireless remote controls with integral wireless transmitter for opera-
tion with the wireless base station.
One Vitotrol 200 RF or one Vitotrol 300 RF can be used for every
heating circuit in a heating system.
The Vitotrol 200 RF can regulate one heating circuit; the
Vitotrol 300 RF up to three heating circuits.

Vitotrol 200 RF

Part no. Z011 219
Wireless subscriber
■ Indications:
– Room temperature
– Outside temperature
– Operating condition
■ Settings:
– Set room temperature for standard mode (day temperature)
Note
The set room temperature for reduced mode (night temperature)
is set at the control unit.
– Operating program
■ Party and economy mode can be enabled via keys
■ Integral room temperature sensor for room temperature hook-up
(only for one heating circuit with mixer)
VITODENS 200-W
1 5
5
Specification
Power supply via KM BUS
Power consumption
Safety category
IP rating
Permissible ambient temperature
– during operation
– during storage and transportation
Setting range of the set room tempera-
ture
Up to three wireless remote controls can be connected to the control
unit.
Note
The wireless remote controls cannot be combined with wired remote
controls.
Installation site:
■ Weather-compensated mode:
Installation anywhere in the building.
■ Room temperature hook-up:
The integral room temperature sensor captures the actual room
temperature and corrects the flow temperature if necessary.
The captured room temperature is dependent on the installation site:
– Main living room on an internal wall opposite radiators.
– Not on shelves or in recesses.
– Never install immediately by a door or heat source (e.g. direct
sunlight, fireplace, TV set, etc.).
Note
Refer to "Wireless accessories" technical guide.
0.5 W
III
IP 30 to EN 60529
Ensure through design/in-
stallation
0 to +40 °C
−20 to +65 °C
3 to 37 °C
VIESMANN
57
5